Thermo finnigan surveyor lcq deca xp plus

Manufactured by Thermo Fisher Scientific
Sourced in United States

The Thermo Finnigan Surveyor-LCQ DECA XP Plus is a liquid chromatography-mass spectrometry (LC-MS) system designed for qualitative and quantitative analysis of a wide range of analytes. It combines a Surveyor high-performance liquid chromatography (HPLC) system with a LCQ DECA XP Plus ion trap mass spectrometer. The system provides high sensitivity, selectivity, and resolution for the identification and quantification of compounds in complex samples.

Automatically generated - may contain errors

2 protocols using thermo finnigan surveyor lcq deca xp plus

1

Liquid Chromatography-Mass Spectrometry Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
For liquid chromatography high-resolution mass spectrometry (LC-HRMS) analysis, an UltiMate 3000 HPLC system (Dionex, Sunnyvale, CA, USA) equipped with a C18 column (5 µm, 4.6 × 250 mm i.d., Agilent Technologies, Palo Alto, CA, USA) was used. The spray voltage was set to 4.0 kV, and the heated transfer capillary temperature was set to 350 °C. High-resolution mass spectrometry analysis was performed with a Thermo Finnigan Surveyor-LCQ DECA XP Plus (Thermo Electron Corporation, San Jose, CA, USA) equipped with an electrospray ionization (ESI) source.
+ Open protocol
+ Expand
2

LC-ESI-MS/MS Analysis of Methanol Extract

Check if the same lab product or an alternative is used in the 5 most similar protocols
The crude methanol extract was fractioned by the high resolution LC-ESI-MS and LC-ESI-MS/MS analysis, which was performed with a Thermo Finnigan Surveyor-LCQ DECA XP Plus (Thermo Electron Corporation, San Jose, CA, USA). The flow rate was maintained at 0.2 mL/min with a gradient of 22 min (0–95 %, vol/vol acetonitrile for 18 min and 95–5%, vol/vol acetonitrile for 4 min). The electrospray needle was operated at a spray voltage of 5 kV, a capillary voltage of 32 V and a capillary temperature of 300°C. For the HCD experiment, helium was used as the collision gas and the collision energy was set at 35%. Elution was monitored by UV detection at 214 nm (Mootz et al., 2000 (link); Deng et al., 2011b (link)).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!