Hp 1050 autosampler

Manufactured by Agilent Technologies
Sourced in United States

The HP 1050 Autosampler is a laboratory equipment designed for automated sample handling and injection. It is capable of handling a wide range of sample vials and provides precise and reliable sample introduction for various analytical techniques.

Automatically generated - may contain errors

5 protocols using hp 1050 autosampler

1

HPLC Quantification of Metformin Derivatives

Check if the same lab product or an alternative is used in the 5 most similar protocols
Concentrations of metformin derivatives were determined by HPLC. The apparatus consisted of an Agilent 1100 binary pump (Agilent Technologies Inc., Wilmington, DE, USA), a 1100 micro vacuum degasser, an HP 1050 Autosampler and an HP 1050 variable wavelength detector, operated at 235 nm. The chromatographic separations were achieved on an Agilent Zorbax SB-C18 analytical column (4.6 mm × 150 mm, 5 μm) (Agilent Technologies Inc., Wilmington, DE, USA) by using isocratic elution of water containing 0.1% formic acid (pH ca. 3.0) and acetonitrile containing 0.1% formic acid with a ratio of 75:25 (v/v). The retention times of the compounds were circa 3.7–4.3 min at a flow rate of 1.0 mL/min at room temperature. The lower limit of quantification for the compounds was 1.0 μM. These HPLC methods were also accurate (100 ± 10% of nominal concentration), precise (RSD% < 10%) and selective (no interfering peaks) over the range 1–100 μM.
+ Open protocol
+ Expand
2

HPLC Analysis of Clobazam Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC analysis was performed using an Agilent 1100 binary pump (Agilent Technologies Inc., Wilmington, DE, USA), a 1100 micro vacuum degasser, a HP 1050 Autosampler, a HP 1050 variable wavelength detector (operated at 235 nm). The chromatographic separations were achieved on a Supelco SupelcosilTM LC-SI analytical column (4.6 mm × 250 mm, 5 μm) (Supelco Inc., Bellefonte, PA, USA) by using isocratic elution of 25 mM of phosphate buffer with 0.3% of triethylamine at pH 4.7 and ACN with 0.1% of formic acid (30:70, v/v). Effluent was monitored at a wavelength of 254.4 nm, with a flow rate of 1.5 mL/min; the injection volume was 5 µL; retention time of 3.7 min. The column was maintained at 40 °C throughout the analysis.
Standard calibration curves were prepared at different dilutions of CZP: in Milli-Q® water/ACN (1:1, v/v) with a linear regression coefficient determined in the range 0.5–200 μg/mL, which was 0.9999; in DMSO with a linear regression coefficient determined in the range 0.1–200 μg/mL, which was 1.
+ Open protocol
+ Expand
3

HPLC Analysis of Melatonin Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC analysis was performed using an Agilent 1100 binary pump (Agilent Technologies Inc., Wilmington, DE, USA), a 1100 micro vacuum degasser, a HP 1050 Autosampler, and a HP 1050 variable wavelength detector (operated at 235 nm). The chromatographic separation was achieved on a Supelco SupelcosilTM LC-SI analytical column (4.6 mm × 250 mm, 5 μm) (Supelco Inc., Bellefonte, PA, USA) by an isocratic elution of a formic acid 0.1% (v/v) solution in Milli-Q® water and a formic acid methanol solution (0.1%, v/v) (40:60, v/v). Effluent was monitored at a wavelength of 278.4 nm, with a flow rate of 1 mL/min; the injection volume was 5 µL, retention time of MEL was 3.5 min. The column was maintained at 45.0 ± 0.2 °C throughout the whole analysis.
The standard calibration curves were prepared at different dilutions of MEL in Milli-Q® water/methanol (1:1, v/v). The linear regression coefficient determined in the range 0.5–200 μg/mL was 0.9999.
+ Open protocol
+ Expand
4

HPLC Analysis of RSV Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC analysis was performed using an Agilent 1100 binary pump (Agilent Technologies Inc., Wilmington, DE, USA), a 1100 micro vacuum degasser, a HP 1050 Autosampler, and a HP 1050 variable wavelength detector (operated at 235 nm). The chromatographic separations were achieved on a ZORBAX® Eclipse XDB-C18 (2.1 mm × 100 mm, 1.8 μm) (Agilent, USA) by using isocratic elution of Milli-Q® water and acetonitrile (75:25, v/v). Effluent was monitored at a wavelength of 310 nm, with a flow rate of 0.3 mL/min; the injection volume was 5 µL; retention time of RSV was 5.2 min. The column was maintained at 45 °C throughout the analysis.
RSV standard calibration curves were prepared in Milli-Q® water/EtOH (20% v/v) with a linear regression coefficient determined in the range 0.1–100 μg/mL was 0.9989. All procedures were carried out to protect the sample from light.
+ Open protocol
+ Expand
5

Quantification of Neurosteroids by HPLC

Check if the same lab product or an alternative is used in the 5 most similar protocols
Concentrations of neurosteroids (111) were determined by HPLC. The apparatus was comprised of an Agilent 1100 binary pump (Agilent Technologies Inc., Wilmington, DE, USA), 1100 micro vacuum degasser, HP 1050 Auto-sampler, HP 1050 variable wavelength detector, operating at 225 nm. The chromatographic separations were achieved on a Supelco Supelcosil LC-Si analytical column (4.6 mm x 250 mm, 5 ml) (Supelco Inc., Bellefonte, PA, USA) by using isocratic elution of water containing 0.1% phosphoric acid and ACN with ratio of 30:70. The retention times of the compounds were ca. 4.3–4.4 min at the flow rate of 1.0 mL/min at room temperature. The lower limit of quantification for the compounds varied from 0.005 to 0.1 μM. These HPLC methods were accurate (100 ± 10% of nominal concentration), precise (RSD% <10%), and selective (no interfering peaks) over the range 0.1–2 μM.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!