The largest database of trusted experimental protocols

Shodex gpc 101

Manufactured by Resonac
Sourced in Japan

Shodex GPC-101 is a gel permeation chromatography (GPC) column designed for the analysis of molecular weight distributions of polymers. It is a key component in GPC systems used for the characterization of various types of macromolecules.

Automatically generated - may contain errors

2 protocols using shodex gpc 101

1

Characterization of PEGylated Silver Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H NMR (400 MHz) and 13C NMR (100 MHz) were measured in CDCl3 using a JNM-ESC400 instrument (JEOL Ltd., Akishima, Japan) at ambient temperature. SEC was performed at 40 °C in THF (flow rate, 1.0 mL/min), using a Shodex GPC-101 (Showa Denko K.K., Tokyo, Japan) gel permeation chromatography system (Shodex DU-2130 dual pump, Shodex RI-71 reflective index detector, and Shodex ERC-3125SN degasser) equipped with a Shodex KF-G guard column (4.6 mm × 10 mm; pore size, 8 μm) and two Shodex KF-804L columns (8 mm × 300 mm) in series. TEM measurements were performed with a JEM-2010 (JEOL Ltd., Akishima, Japan) operated at 200 kV. The size distribution of AgNPs was determined by the average of 150–200 observed particles. UV–Vis absorption spectra were recorded on a JASCO 4100 spectrophotometer (JASCO Co., Tokyo, Japan) at 25 °C. Relative UV–Vis absorption intensity (A/A0 × 100%) of AgNPs without and with NaCl was compared at λmax (409, 405, and 420 nm for HO–PEG5k–OH, c-PEG5k, and MeO–PEG5kOme, respectively). MALDI–TOF mass spectrometry was carried out using a Bruker Daltonics Ultraflex-S at the Open Facility, Hokkaido University, Hokkaido, Japan.
+ Open protocol
+ Expand
2

GPC Analysis of Sodium Polystyrene Sulfonate

Check if the same lab product or an alternative is used in the 5 most similar protocols
GPC analysis of PSSNa was performed on a Shodex GPC-101 (Showa Denko K.K., Japan) equipped with two Shodex gel columns at a flow rate of 0.8 mL min À1 using a water/acetonitrile (6/4) mixture with 10 mM LiCl as the eluent (40 1C). The column system was calibrated using standard PSSNa.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!