The largest database of trusted experimental protocols

Mcc 340

Manufactured by Thermo Fisher Scientific
Sourced in United States

The MCC 340 is a laboratory instrument used for monitoring and controlling temperature-dependent processes. It features a digital display and supports a range of temperature sensors.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using mcc 340

1

Quantifying Cytokine Expression in Fibroblasts

Check if the same lab product or an alternative is used in the 5 most similar protocols
ELISA experiments were performed with fibroblast culture supernatant, TNF-α, and IL-1β ELISA kits, according to the manufacturer's instructions. The cell culture supernatant (100 μL) was pipetted into a 96-well plate to incubated for 2 hours, then washed 3 times with washing buffer, then the well plate was dried before 200 μL of substrate (tetramethylbenzopyridine) was added to every in the well. Let it react for 20 minutes. Plates were read by using an MCC 340 multi-scan plate reader (Thermo Fisher Scientific Inc, Pittsburgh, PA) at a wavelength of 450 nm. The expression of TNF-α and IL-1β in the samples were determined by comparison with a standard curve generated using a manufacturer-provided standard. The standard curve was completed by plotting average O.D. (450 nm) acquired for each concentration on the “Y” axis and average O.D. (450 nm) for the corresponding concentration on the horizontal (“X”) axis.
+ Open protocol
+ Expand
2

HUVEC Proliferation Viability Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cell proliferative viability of HUVECs was examined using CCK-8 commercial kit (Cat. No. C0038, Beyotime Biotech.) based on protocol of the manufacturer. Briefly, HUVECs were cultured to the dosage of 1×10 5 cells/ml and treasfected with microRNA-126 inhibitor and microRNA-126 control plasmids. Then, the transfected HUVECs were cultured for 24 h and administrated with CCK-8 regent for 4 h at 37 ℃ (at final dosage of 10 μl/ml).
At last, proliferative viabilities of HUVECs were evaluated using a micro-plate reader (Mode: MCC/340, Thermo Fisher Scientific, Hudson, NH, USA) at 450 nm.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!