The largest database of trusted experimental protocols

60 f254s plates

Manufactured by Merck Group
Sourced in Germany

The 60 F254S plates are thin-layer chromatography (TLC) plates manufactured by Merck Group. These plates are coated with a fluorescent indicator silica gel, which allows for the visualization of separated compounds under ultraviolet (UV) light. The plates are designed for analytical and preparative TLC applications.

Automatically generated - may contain errors

2 protocols using 60 f254s plates

1

Reverse-Phase HPTLC Quantification of Caffeine

Check if the same lab product or an alternative is used in the 5 most similar protocols
The reverse-phase HPTLC analysis was performed using the CAMAG HPTLC instrument (CAMAG, Muttenz, Switzerland). The estimation of caffeine was performed on 10 × 20 cm glass plates precoated with reverse-phase silica gel 60 F254S plates (E-Merck, Darmstadt, Germany). The samples to the reverse-phase TLC plates were spotted as the 6 mm bands utilizing a CAMAG Automatic Sampler 4 (ATS4) applicator (CAMAG, Geneva, Switzerland). The sample applicator was fitted with CAMAG Microliter Syringe (Hamilton, Bonaduz, Switzerland). The application rate for caffeine estimation was constant at 150 nL s−1. The TLC plates were developed in an Automatic Developing Chamber 2 (ADC 2) (CAMAG, Muttenz, Switzerland) to a distance of 80 mm using EtOH-water (55:45, v v−1) greener mobile phase. The development chamber was saturated with vapors of EtOH-water (55:45, v v−1) for 30 min at 22 °C. Caffeine was detected using a wavelength of 275 nm at a scanning rate of 20 mm s−1 and slit size set to 4 × 0.45 mm.
+ Open protocol
+ Expand
2

Simultaneous RP-HPTLC-Densitometry Analysis of 6-SHO and 6-GIN

Check if the same lab product or an alternative is used in the 5 most similar protocols
Simultaneous RP-HPTLC-densitometry analysis of 6-SHO and 6-GIN was carried out using the following instrumentation and analytical conditions:
HPTLC apparatus: CAMAG TLC system (CAMAG, Muttenz, Switzerland)
Software: WinCAT’s (version 1.4.3.6336, CAMAG, Muttenz, Switzerland)
Syringe for sample application: CAMAG microliter Syringe (Hamilton, Bonaduz, Switzerland)
TLC plate: 10 × 20 cm glass backed plates pre-coated with RP silica gel 60 F254S plates (E-Merck, Darmstadt, Germany)
Sample applicator: CAMAG Linomat-V (CAMAG, Muttenz, Switzerland)
Gas for sample application: nitrogen
Development chamber: CAMAG automatic developing chamber 2 (ADC2) (CAMAG, Muttenz, Switzerland)
TLC scanner: CAMAG TLC scanner-III (CAMAG, Muttenz, Switzerland)
Stationary phase: 10 × 20 cm glass backed plates pre-coated with RP silica gel 60 F254S plates (E-Merck, Darmstadt, Germany)
Mobile phase for 6-SHO and 6-GIN: ethanol:water (6.5:3.5 v/v)
Saturation time: 30 min at 22 °C
Development distance on plate: 80 mm
Development mode: linear ascending mode
Sample application rate: 150 nL/s
Densitometry of scanning mode: absorbance/reflectance.
Scanning wavelength for 6-SHO and 6-GIN: 200 nm
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!