Accutof lc plus jms t100lp mass spectrometer

Manufactured by JEOL
Sourced in Japan

The AccuTOF LC-plus JMS-T100LP is a high-resolution time-of-flight mass spectrometer designed for liquid chromatography applications. It provides accurate mass measurements and high-quality mass spectral data for the identification and characterization of chemical compounds.

Automatically generated - may contain errors

2 protocols using accutof lc plus jms t100lp mass spectrometer

1

Instrumental Analysis for Chemical Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
JEOL ECA600, ECZ400 and ECZ600 were used for recording spectra of nuclear magnetic resonance (NMR) spectra. JASCO FT/IR-4700 spectrometer was used for recording IR spectra. JEOL AccuTOF LC-plus JMS-T100LP mass spectrometer was used for obtaining HRMS spectra. JASCO an LC-2000 Plus series were used for high-performance liquid chromatography (HPLC).
+ Open protocol
+ Expand
2

Isothermal Decomposition of PMMA

Check if the same lab product or an alternative is used in the 5 most similar protocols
The isothermal decomposition of PMMA was analyzed with an Accu-ToF LC-plus JMS-T100 LP mass spectrometer JEOL (Tokyo, Japan) working with a direct-analysis-in-real-time (DART) ion source (Ion Sense, Saugus, MA, USA). The sample was used without any prior preparation. The fragments that resulted from the decomposition process were evaporated in a stream of helium atmosphere heated at constant temperatures of 200, 250, 300, 350, 400, 450, 500 and 550 °C. The heated helium/vapor mixture was then ionized by excited metastable helium atoms before entering the ion source of the time-of-flight mass spectrometer. All the samples were analyzed with DART-ToF-MS using the Accu-TOF mass spectrometer acquired from JEOL (Tokyo, Japan). The experimental conditions were as follows: vacuum level 1.3 × 105 Pa, He used as a heating and ionization gas, ring lens with a voltage of 4 V, peaks voltage of 500 V, and a mass resolution that ranged between 3600 and 4900. The sample (1–2 mg) in powder form was placed in a small piece of sandpaper and introduced between the DART outlet and the MS port inlet, and polyethylene glycol (104 g·mol−1) was used in this work for calibration.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!