The largest database of trusted experimental protocols

Digidata 1322 a ad da converter

Manufactured by Molecular Devices

The Digidata 1322A is an analog-to-digital (AD) and digital-to-analog (DA) converter that can be used to interface electrophysiology and other scientific instruments with a computer. It provides high-speed, high-resolution data acquisition capabilities.

Automatically generated - may contain errors

4 protocols using digidata 1322 a ad da converter

1

Oocyte Electrophysiology with Micropipettes

Check if the same lab product or an alternative is used in the 5 most similar protocols
Microelectrodes made from capillary pipettes were cut with resistance in the 0.3–2 MΩ range and filled with 3 M KCl. An oocyte was penetrated by two electrodes and whole-oocyte currents were measured with perfusion of extracellular solutions. Currents and voltages were obtained using a Geneclamp 500B amplifier and Digidata 1322 A AD/DA converter (Molecular Devices, Union City, CA) at 200 μs/sample and Bessel filtered at 2 kHz. The files were analyzed with pClamp 11 (Axon Instruments, Union City, CA) and data plotted with GraphPad Prism 8 (GraphPad Software, San Diego, CA).
+ Open protocol
+ Expand
2

Two-Microelectrode Voltage Clamp of Oocytes

Check if the same lab product or an alternative is used in the 5 most similar protocols
Two-microelectrode voltage clamp experiments were performed as described before9 (link). Briefly, the two electrodes (Capillary pipettes, Warner Instruments, Hamden, CT) impaling oocytes were filled with 3 M KCl to form a tip resistance of 0.3–2 MΩ. The standard extracellular solution (pH 7.5) containing 100 mM NaCl, 2 mM KCl, 1 mM MgCl2 and 10 mM HEPES was used. The solution containing extracellular Ca2+ was prepared from the standard solution with the addition of CaCl2 to a final concentration of 5 mM. Duration of application of Ca2+ medium was indicated in time course recordings. Oocyte whole-cell currents were recorded using a Geneclamp 500B amplifier and Digidata 1322A AD/DA converter (Molecular Devices, Union City, CA). The pClamp 9 software (Axon Instruments, Union City, CA) was applied for data acquisition and analysis. Currents and voltages were digitally recorded at 200 μs/sample and filtered at 2 kHz through a Bessel filter. SigmaPlot 12 (Systat Software, San Jose, CA) was used for data fitting and plotting.
+ Open protocol
+ Expand
3

Two-electrode voltage clamp of oocytes

Check if the same lab product or an alternative is used in the 5 most similar protocols
Two-electrode voltage clamp experiments using oocytes were carried out as previous61 (link). Briefly, two electrodes made of capillary pipettes (Warner Instruments, Hamden, CT) penetrating an oocyte were filled with 3 M KCl to obtain a tip resistance ranging from 0.3 to 2 MΩ. Whole-cell currents of an oocyte were recorded at RT in an extracellular solution with composition specified in figure legends. Electric currents were recorded with a Geneclamp 500B amplifier and Digidata 1322 A AD/DA converter (Molecular Devices, Union City, CA). Currents and voltage were recorded at 200 μs/sample and Bessel filtered at 2 kHz. The data was acquainted and analyzed with software pClamp version 9 (Axon Instruments, Union City, CA). SigmaPlot version 13 (Systat Software, San Jose, CA) and GraphPad Prism version 7 (GraphPad Software, San Diego, CA) were employed for data plotting.
+ Open protocol
+ Expand
4

Two-Electrode Voltage Clamp in Xenopus Oocytes

Check if the same lab product or an alternative is used in the 5 most similar protocols
The two-electrode voltage clamp electrophysiology experiments in Xenopus oocytes were performed as we described previously (Zheng et al., 2018a) . Briefly, an electrode made of a capillary glass pipette (Warner Instruments, Hamden, CT) was filled with 3 M KCl and impaled an oocyte to form a tip resistance of 0.3-2 MΩ. The Geneclamp 500B amplifier and Digidata 1322A AD/DA converter (Molecular Devices, Union City, CA) were used to record the wholecell currents and membrane potentials. The pClamp 9 software (Axon Instruments, Union City, CA) was used to acquire and analyze the data. Both signals were digitized at 200 μs/sample and filtered at 2 kHz through a Bessel filter. Data were plotted using SigmaPlot 13 (Systat Software, San Jose, CA) or GraphPad Prism 8 (GraphPad Software, San Diego, CA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.