Masshunter workstation software version b 06

Manufactured by Agilent Technologies
Sourced in United States

MassHunter workstation software version B.06.00 is a software application developed by Agilent Technologies for the analysis of mass spectrometry data. The software provides users with tools for data acquisition, processing, and reporting.

Automatically generated - may contain errors

3 protocols using masshunter workstation software version b 06

1

UHPLC-ESI-QTOF Analysis of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
An Agilent high-resolution Q-TOF system series 6520 and UHPLC system series 1290 and Zorbax Eclipse-C18 HD (2.1 × 50 mm, dp = 1.8 μm) column was used for UHPLC–ESI-QTOF analysis. For control of the system, data acquisition, qualitative and quantitative analysis, MassHunter workstation software version B.06.00 (Agilent Technologies, Santa Clara, CA, USA) was used. To ensure accuracy in mass measurements, a reference mass correction was provided by using masses 121.050873 and 922.009798 as lock masses. The conditions for performing chromatography were optimized based on previous studies [17 (link)]. All of the chromatographic and spectrometric parameters are described in Table 3.
+ Open protocol
+ Expand
2

Optimized UHPLC-HRMS Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The conditions for performing chromatography were optimized based on previous studies. The LC–MS analysis was conducted using an Agilent high-resolution Q-TOF system series 6520 equipped with an electrospray ionization source (ESI) and UHPLC system series 1290. For the analysis, a Kinetex-C18 (2.1 mm × 50 mm, dp = 1.7 μm) reversed-phase chromatographic column with a C18 precolumn guard (Phenomenex, Torrance, CA, USA) was employed. The MassHunter workstation software version B.06.00 (Agilent Technologies, Santa Clara, CA, USA) was used to control of the UHPLC-HRMS system, manage data acquisition, and perform qualitative and quantitative analysis. To ensure accuracy in mass measurements, a reference mass correction was implemented by utilizing lock masses of 121.050873 and 922.009798 (API-TOF Reference Mass Solution Kit; Agilent Technologies, Santa Clara, CA, USA). The process of optimizing instrument conditions commenced with the tunning of the MS detector in a positive mode operating within an extended dynamic range (2 GHz). Detailed information regarding the chromatographic and spectrometric parameters can be found in Table S1.
+ Open protocol
+ Expand
3

Agilent 6540 QTOF-MS for Metabolomic Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mass spectrometry was performed using an Agilent 6540 QTOF–MS (Agilent Corp., USA) equipped with a Dual AJS electrospray ionization (ESI) source, and the following operating parameters were used: positive mode, drying gas (nitrogen, N2); flow rate, 8.0 L/min; gas temperature, 325 °C; nebulizer, 40 psig; sheath gas temperature, 350 °C; sheath gas flow, 11 L/min; capillary voltage, 4000 V; skimmer, 65 V; OCT 1 RF Vpp, 750 V; fragmentor, 110 V. The sample collision energy was set at 10, 20, 30 and 40 V. All the operations, acquisition, and analyses of data were controlled by Agilent LCMS-QTOF Mass Hunter Acquisition Software Ver. B.06.00 (Agilent Technologies Inc.) and operated under Mass Hunter Workstation Software Version B.06.00 (Agilent Technologies Inc.).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.