The largest database of trusted experimental protocols

5 protocols using cd21 pe cy5

1

Multiparameter Flow Cytometry Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
After 6 days culture, cultured cells were analyzed for expression of surface markers by multi-color flow cytometry. Cell aliquots were treated with anti-human Fc mAb for 20 minutes and stained for 30 minutes with selected combinations of fluorochrome-conjugated antibodies.
For the analysis of B cell subpopulations and activation markers, the monoclonal antibodies used were CD19-PE-CF594 (BD Biosciences, San Jose, CA), CD62L-PE-Cy5 (BD Biosciences), IgD-FITC (BD Biosciences), CD27-PE-Cy7 (BD Biosciences), CD24-PE (BD Biosciences), CD38-PerCP-Cy5.5 (Beckman Coulter, Brea CA), CD138-PE-Cy7 (eBioscience, San Diego, CA), CD23-PE (BD Biosciences), CD21-PE-Cy5 (BD Biosciences), IgG-PC7 (BD Biosciences), CD86-Alexa 700 (BD Biosciences) and CD95-Pacific Blue (BioLegend, San Diego, CA).
For plasma cell staining, cultured cells were first incubated with monoclonal antibodies to surface markers (CD38, CD138 and CD19), fixed and permeabilized with Cytofix/Cytoperm Fixation/Permeabilization Solution Kit (BD Biosciences) and then incubated with Blimp-1-PE (R&D systems) and Pax5-APC (eBioscience) for 30 minutes.
For the proliferation assay, 1–10×106 cells of interest were labeled with 1μM carboxyfluorescein succinimidyl ester (CFSE) (Invitrogen) before culture initiation. After 6 days of culture, cells were harvested, incubated with antibodies, and dilution of CFSE was assessed by flow cytometry.
+ Open protocol
+ Expand
2

Flow Cytometry of Immune Cell Subsets

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following fluorochrome conjugated antihuman monoclonal antibodies (MoAbs) were used for flow cytometry studies: ICOSBV421, ICOSAlexa488, CD40LBV605, CD69BV650, HLA-DRFITC, CD38APCCy7, and TNF-αAPCCy7 from BioLegend (San Diego, CA); CD3BUV395, CD4PerCPCy5.5, CD8Alexa-Fluor700, CCR7PECF594, IL-2BV711, CXCR5Alexa647, IFNγPE-Cy7, PD1BV650, CD45ROAPCH7, CD21PECy5, CD27PerCPCy5.5, IgDFITC, CD10PECy7, and CD20Alexa700 from BD Bioscience (San Jose, CA); IL-21PE, CD27PECy5, and IL-17Alexa488 from e-Biosciences (San Diego, CA); and CD45ROPE-TexasRed from Beckman Coulter (Fullerton, CA). Live/Dead Fixable Aqua Dead Cell Stain Kit and CellTrace Violet Cell Proliferation Kit were from ThermoFisher (Boston, MA). Recombinant human IL-21 (Cat #8879-IL-010) from R&D systems, purified antihuman IL-2 (Cat #3440-ON-500) and antihuman-IL-21 (Cat #MT216G/21.3m) from Mabtech, and antihumanTNF-α (Cat #502922) from BioLegend were used. Samples were acquired on a BD LSRFortessa (BD Biosciences, CA) flow cytometer and analyzed by FlowJo V10 (TreeStar, Inc).
+ Open protocol
+ Expand
3

Flow Cytometric Analysis of Human B Cell Subsets

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mononuclear cells were isolated from peripheral blood using ficoll density gradient centrifugation and stained with the following anti-human antibody staining reagents: Goat F(ab')2 Anti-Human IgD- FITC (Invitrogen) or -APC (clone: IgD26, Miltenyi Biotec); Goat F(ab')2 Anti-Human IgM-PE-Cy5; CD3-Pacific Orange (clone: UCHT1), CD14-Pacific Orange (clone: TK4); CD24-PE-A610 (clone: SN3; Invitrogen); CD19-APC-Cy7 (clone: SJ25C1); CD38-Pacific Blue (clone: HB7); CD23-PE-Cy7 clone: M-L233); CD21-PE-Cy5 (clone B-ly4); CD27-PE (clone: L128, BD Pharmingen); CD138-APC (clone: 44F9, Miltenyi Biotec) and mitotracker green. Approximately 0.1–3 × 105 cells were collected for each population using a BD FACS Aria II (BD Biosciences).
+ Open protocol
+ Expand
4

Flow Cytometric Analysis of Human B Cell Subsets

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mononuclear cells were isolated from peripheral blood using ficoll density gradient centrifugation and stained with the following anti-human antibody staining reagents: Goat F(ab')2 Anti-Human IgD- FITC (Invitrogen) or -APC (clone: IgD26, Miltenyi Biotec); Goat F(ab')2 Anti-Human IgM-PE-Cy5; CD3-Pacific Orange (clone: UCHT1), CD14-Pacific Orange (clone: TK4); CD24-PE-A610 (clone: SN3; Invitrogen); CD19-APC-Cy7 (clone: SJ25C1); CD38-Pacific Blue (clone: HB7); CD23-PE-Cy7 clone: M-L233); CD21-PE-Cy5 (clone B-ly4); CD27-PE (clone: L128, BD Pharmingen); CD138-APC (clone: 44F9, Miltenyi Biotec) and mitotracker green. Approximately 0.1–3 × 105 cells were collected for each population using a BD FACS Aria II (BD Biosciences).
+ Open protocol
+ Expand
5

Multiparameter Flow Cytometry Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
The following anti-human monoclonal antibodies were utilized for flow cytometry studies: CD20Alexa700, CD27PerCP-Cy5.5, CD38APC-Cy7, Ki67BUV705 from BioLegend (San Diego, CA); CD3BUV395, CD10PE-Cy7, CD21PE-Cy5, PDL1BUV650, CD4PerCP-Cy5.5, PD1BV605 from BD Bioscience (San Jose, CA) and IgDFITC from Southern Biotech. Live/Dead® Fixable Aqua Dead Cell Stain Kit (ThermoFisher) was used for exclusion of dead cells.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists