The largest database of trusted experimental protocols

3 protocols using cyclohexanone

1

Comparative Analysis of Edible Oil Oxidation

Check if the same lab product or an alternative is used in the 5 most similar protocols
The three oils used in this study were coconut oil (Organic extra virgin coconut oil from PLANTIS®, Barcelona, Spain), rapeseed oil (Organic cold pressed rapeseed oil Terpenic lab S.L., Barcelona, Spain) and grape seed oil (Refined grape seed Terpenic lab S.L., Barcelona, Spain). Three different batches of each type of oil were purchased in a local market.
2-thiobarbituric acid, and fatty acid methyl esters were obtained from Sigma-Aldrich Chemical (Steinheim, Germany). Boron/methanol trifluoride and heptane were purchased from Merck (Whitehouse Station, NJ, USA). Potassium hydroxide, hexane, cyclohexanone, hydrochloric acid, trichloroacetic acid and ammonium sulfate were from Panreac (Barcelona, Spain).
Salmonella typhimurium strains TA97a and TA98 and the Mutazime S9 mix at 10% from livers of Aroclor 1254-induced rats were purchased from Moltox (Boone, NC, USA). Nutrient broth and Phosphate Buffered Saline (PBS) tablets were obtained from Oxoid (Basingtone, UK). 4-nitro-o-phenylenediamine (NPD), 2-aminoanthracene (AA) and 2-aminofluorene (AF), histidine and biotin were obtained from Sigma-Aldrich.
+ Open protocol
+ Expand
2

Meat and Fat Composition Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fresh beef and pork meat (loin) and pork back fat were obtained from a local meat market. Sunflower oil (Urzante S.L, Navarra, Spain) was obtained in a local market.
Carrageenan (kappa-carrageenan) was kindly donated by Cargill (San Sebastián, Spain).
Cholesterol, 5α-cholestane, thiobarbituric acid, fatty acid methyl esters and Polysorbate 80 were purchased from Sigma-Aldrich Chemical (Steinheim, Germany). 19hydroxycholesterol was obtained from Steraloids (Wilton, NH, USA). Tri-sil® reagent was obtained from Pierce (Rockford, IL, USA). Acetone, chloroform, ethyl acetate, methanol, hexane, 2-propanol, hydrochloric acid, cyclohexanone, trichloroacetic acid, potassium chloride, potassium hydroxide, anhydrous sodium sulphate and sodium phosphate were obtained from Panreac (Barcelona, Spain). hexane for gas chromatography, dichloromethane for gas chromatography and boron trifluoride/methanol were from Merck (Whitehouse Station, NJ, USA). Strata NH 2 (55 µm, 70 A) 500 mg/3 mL Solid Phase Extraction cartridges were obtained from Phenomenex (Torrance, CA, USA).
+ Open protocol
+ Expand
3

Comprehensive Lipid Extraction and Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cholesterol, stigmasterol, 5α-cholestane, heptadecanoic acid, α-tocopherol, tocopherol acetate, ammonium thyocianate and thiobarbituric acid were purchased from Sigma-Aldrich Chemical (Steinheim, Germany). 19-hydroxyCholesterol was obtained from Steraloids (Wilton, NH, USA). Tri-sil ® reagent was obtained from Thermo-Scientific (Rockford, IL, USA). Hexane, heptane, acetone, chloroform, ethyl acetate, butanol, methanol, 2-propanol, hydrochloric acid, cyclohexanone, trichloroacetic acid, potassium chloride, potassium hydroxide, ammonium iron (II) sulphate, barium chloride, anhydrous sodium sulphate and sodium phosphate were obtained from Panreac (Barcelona, Spain). Strata NH 2 (55 µm, 70 A) 500 mg / 3 mL Solid Phase Extraction cartridges were obtained from Phenomenex (Torrance, USA). Sunflower oil was purchased in a major local distributor.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.