The largest database of trusted experimental protocols

4 4 6 dimethoxy 1 3 5 triazin 2 yl 4 methylmorpholinium chloride

Manufactured by Tokyo Chemical Industry
Sourced in Japan

4-(4,6-Dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride is a chemical compound. It is a white crystalline solid. The chemical formula is C10H17ClN4O2.

Automatically generated - may contain errors

4 protocols using 4 4 6 dimethoxy 1 3 5 triazin 2 yl 4 methylmorpholinium chloride

1

HA-based Biomaterial Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
HA (90 kDa) was kindly donated by JNC Corporation (Japan). EGCG was obtained from DSM Nutritional Products (Switzerland). Dextran (100 kDa), bovine serum albumin (BSA), phosphate-buffered saline (PBS) and incomplete Freund's adjuvant were purchased from Sigma-Aldrich (USA). Fetal bovine serum (FBS) and PicoGreen dsDNA assay kit were purchased from Thermo Fisher (Singapore). Tumor necrosis factor-alpha (TNFα) was purchased from R&D System (USA). Bovine type II collagen was obtained from Chondrex (USA). 2-(N-Morpholino)ethanesulfonic acid (MES), N-hydroxysuccinimide (NHS), 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC·HCl), 5-aminofluorescein (AF) and 4,6-diamidino-2-phenylindole (DAPI) were purchased from Sigma-Aldrich (Singapore). 4-(4,6-Dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride (DMTMM) was acquired from Tokyo Chemical Industry Co. Ltd. (Japan). Cyanine7.5 amine dye (Cy7.5) was obtained from Lumiprobe Corporation (USA). Rat anti-human CD44 antibody (clone Hermes-1), isotype control antibody, fluorescein isothiocyanate (FITC)-labeled secondary antibody, Pierce™ quantitative peroxide assay kit and alamarBlue® cell viability assay reagent were purchased from Thermo Fisher Scientific (Singapore). CellTiter-Glo® luminescent cell viability assay reagent was obtained from Promega (Singapore).
+ Open protocol
+ Expand
2

Synthesis of a Fluorescent Probe

Check if the same lab product or an alternative is used in the 5 most similar protocols
2-[4-(2-Hydroxyethyl)-1-piperazinyl]ethanesulfonic acid (HEPES), Acetonitrile (Luminasol), sodium hydroxide, and sodium nitrate were purchased from Wako Pure Chemical Industries, Ltd. (Osaka, Japan). 7-Hydroxycoumarin-3-carboxylic acid, 2,2′-dipicolylamine, 4-(4,6-dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride (DMT-MM), and formaldehyde (37% aqueous solution) were purchased from Tokyo Chemical Industry, Co., Ltd. (Tokyo, Japan). Acetonitrile, chloroform, and chloroform-d were purchased from Kanto Chemical, Co., Inc. (Tokyo, Japan). Sodium dihydrogen phosphate was purchased from Sigma-Aldrich Japan, Co., LLC. (Tokyo, Japan).
All other organic solvents and reagents were commercially available with guaranteed grades and used without further purification. Water was doubly distilled and deionized by a Milli-Q water system (WG222, Yamato Scientific Co., Ltd., Tokyo, Japan and Autopure WR-600G, Merck Millipore, MA, USA) before use.
+ Open protocol
+ Expand
3

Synthesis of Polymerized PEG-Conjugates

Check if the same lab product or an alternative is used in the 5 most similar protocols
Acrylic acid (AA, 99.5%) stabilized with 200 ppm 4-methoxyphenol, methanol (99.8%), and sodium borate buffer were obtained from VWR (Radnor, PA, USA). 4,4′-Azobis-(4-cyanopentanoic acid) (A-CPA) and 4-cyano-4-(phenylcarbonothioylthio)pentanoic acid (CPA-DB) (>97% HPLC) was obtained from Sigma-Aldrich (St. Louis, MO, USA). Methoxy-poly(ethylene glycol)-amine powder (PEG-NH2) was obtained from Jenkem Technologies (Beijing, China) and 4-(4,6-dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride (DMTMM) was obtained from TCI America (Portland, OR, USA). All chemicals were used as received unless otherwise specified.
+ Open protocol
+ Expand
4

Recombinant Galectin-1 and Galectin-3 Production

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents were used as received unless otherwise noted. Acrylic acid (monomer), 4,4′-azobis(4-cyanopentanoic acid) (radical initiator), and 4-cyano-4-(phenylcarbonothioylthio)pentanoic acid (chain transfer agent, CTA) were purchased from Sigma-Aldrich. D-Glucose, D-galactose, D-lactose monohydrate, D-maltose monohydrate, maltotriose, ammonium carbamate, ammonium hydroxide solution (28.0−30.0% NH3), and tris(2-carboxyethyl)phosphine hydrochloride were purchased from Sigma-Aldrich. 4-(4,6-Dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride (DMTMM) was purchased from TCI America. Octyl maleimide was purchased from Santa Cruz Biotechnology, Inc. HBS buffer (10 × 10−3 M 4-(2-hydroxyethyl)-1-piperazine-ethanesulfonic acid (HEPES), 150 × 10−3 M NaCl, pH 7.2) was prepared with deionized (DI) water and filtered through a 0.2 μm PES membrane. Recombinant human galectin-1 and galectin-3 constructs were obtained from C. Bertozzi, recombinantly expressed in XL1-Blue competent E. coli, and purified using β-lactosyl sepharose affinity chromatography methods, as previously reported.42 (link)
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!