The largest database of trusted experimental protocols

Fused silica 24 ga

Manufactured by Merck Group
Sourced in United States

Fused Silica 24 Ga is a type of lab equipment made of high-purity fused silica. It is a rigid, non-porous material with excellent thermal and chemical resistance properties.

Automatically generated - may contain errors

3 protocols using fused silica 24 ga

1

Volatile Compounds Analysis of Eggs

Check if the same lab product or an alternative is used in the 5 most similar protocols
The control and treated eggs were put in 20 mL headspace extraction bottles.
CAR/PDMS Fused Silica 24 Ga (Manual Holder, 3pk; Supelco, Bellefonte, PA, USA)
extracted for 2 h, desorbed in the GC-MS inlet for 5 min, and determined
volatile flavor compounds. GC-MS conditions: Agilent 7890B/5977A (Agilent, Santa
Clara, CA, USA) GC-MS, HP-5 (30 m ×0.25 mm×0.25 mm) column, inlet
temperature 230°C, split less injection. Heating program: the initial
temperature was 40°C, maintained for 6 min, increased to 135°C at
a heating rate of 3°C/min, and then increased to 230°C at a
heating rate of 6°C/min and held for 10 min. Mass spectrometry
conditions: EI ion source, ion source temperature 200°C, electron
capacity 70 ev, filament current 150 μA, scanning mass range
33–450 u.
+ Open protocol
+ Expand
2

Volatile Organic Compound Profiling in Fermentation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Volatile organic compound (VOC) profiles were determined following procedures described by Zou et al. [11 (link)], with some modifications. Samples of the FCRB and TFRB were stored at 4 °C before analysis, and 1 µL 2-octanol internal standard and 2 g NaCl were added to each 8 mL sample in a 20 mL vial and tightly capped with a PTFE/silicone septum. Carboxen/polydimethylsiloxane (CAR/PDMS) SPME fibers (75 µm, Fused Silica 24 Ga, Manual Holder, 3 pk, Supelco, Bellefonte, PA, USA) were used for VOC extraction at 60 °C for 50 min. Compounds were desorbed for 5 min at 280 °C in splitless mode, using a 0.75 mm dedicated SPME liner.
Gas chromatography conditions, MS operating conditions, and qualitative and semi-quantitative analysis were all performed according to the method described by Zou et al. [11 (link)].
+ Open protocol
+ Expand
3

Solid-Phase Microextraction (SPME) Fiber Selection

Check if the same lab product or an alternative is used in the 5 most similar protocols
The SPME fiber assembly kit assortment, Stableflex 24Ga, manual holder, 4pk fibers and PDMS/DVB (divinylbenzene), fused silica 24 Ga, SPME holder and SPME manifold were supplied by Supelco. The fibers selected were PDMS/DVB and PDMS/DVD+OC (organic carbon) with film thickness diameter 65 µm, polyacrylate 85 µm, Carboxen™/PDMS 85 µm and DVB/CAR/PDMS 50/30 µm. Fibers were conditioned with the set up parameters and tested without further modification. To eliminate potential problems with carry over and baseline noise, blank injections were performed between runs.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists