The largest database of trusted experimental protocols

200fr autoanalyser

Manufactured by Toshiba
Sourced in Japan

The Toshiba 200FR Autoanalyser is a laboratory instrument designed for automated chemical analysis. It is capable of performing a variety of analytical tests on samples, including those commonly used in clinical, industrial, and research settings. The core function of the Toshiba 200FR Autoanalyser is to automatically measure and analyze the concentrations of different analytes in a given sample.

Automatically generated - may contain errors

2 protocols using 200fr autoanalyser

1

Cardiometabolic Biomarker Measurements

Check if the same lab product or an alternative is used in the 5 most similar protocols
Systolic and diastolic blood pressures were measured on the left upper arm after 5 minutes of rest in a sitting position using an automatic blood pressure monitor (HEM-907-E; OMROM, Tokyo, Japan). Abdominal circumference was measured in a standing position at the midway between the lower costal margin and the iliac crest. After fasting for 8 hours or more, blood was drawn from the antecubital vein of each participant. The samples were properly processed, refrigerated at 2℃ to 8℃, and analyzed within 24 hours of transportation. Fasting glucose was measured using a Hitachi Automatic Analyzer 7600 (Hitachi, Tokyo, Japan). High-performance liquid chromatography-723G7 (Tosoh, Tokyo, Japan) was used to check HbA1c. Insulin concentrations were estimated using an electrochemiluminescence method (COBAS E 411; Roche Diagnostics, Mannheim, Germany). The intra-assay and interassay coefficients of variation for the biochemical assays ranged between 3.1% and 7.6%. The blood levels of total cholesterol, triglycerides, high density lipoprotein, and low density lipoprotein cholesterol levels were measured using a Toshiba 200FR Autoanalyser (Toshiba Medical Systems Co. Ltd., Tokyo, Japan). High-sensitivity C-reactive protein was measured with an immunoturbidimetric method (CRP II Latex X2; Denka Seiken Co. Ltd., Tokyo, Japan) using an autoanalyzer (Toshiba).
+ Open protocol
+ Expand
2

Anthropometric and Metabolic Measurements Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Height and body mass were measured with the participants wearing light clothing and no shoes. BMI was calculated as body mass in kilograms divided by the square of the height in meters. WC (in cm) was measured mid-way between the costal margin and the iliac crest at the end of normal expiration. BP was measured on the right arm after resting for 5 min using an automatic manometer with an appropriate cuff size. After overnight fasting, early-morning blood samples were drawn from the antecubital vein into vacuum tubes and subsequently analysed by the central, certified laboratory at AMC. Measurements included concentrations of fasting glucose, insulin, hsCRP, several lipid parameters and liver enzymes.
Fasting total cholesterol, HDL-C, LDL-C, TG, uric acid, AST and ALT levels were measured using enzymatic colorimetric methods on a Toshiba 200FR Neo analyser (Toshiba Medical System Co., Ltd.). GGT was measured using the L-g-glutamyl-p-nitroanilide method (Toshiba Medical System Co., Ltd.). FPG and hsCRP were measured using the enzymatic colorimetric method on the Toshiba 200 FR auto-analyser and the immunoturbidimetric method (Toshiba Medical System Co., Ltd.), respectively. Ion-exchange high-performance liquid chromatography (Bio-Rad Laboratories, Inc., Hercules, CA, USA) was used to measure the HbA1c levels. All enzyme activities were measured at 37 °C.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!