The measurement of organic and inorganic ions was performed on an HPLC (Prominence, Shimadzu). The chromatographic system consisted of a Shimadzu Model system controller (SLC-10AVP), conductivity detector (CDD-10ADVP), and column oven (CTO-20A). K- and Na+ were separated using a LC-10ADVP pump, a column Shim-pack IC-C4 (150 mm × 4.6 mm) and a guard column Shim-pack IC-GC4 (10 mm × 4.6 mm) with a mobile phase (3.2 mM Bis-Tris, 8 mM p-hydroxybenzoic acid, 50 mM Boric acid) and a flow rate of 1.0 ml min-1 at 40°C. Cl- and Malate2- were separated with a LC-20AD pump, a column Shim-pack IC-A3 (150 mm × 4.6 mm) and guard column Shim-pack IC-GA3 (10 mm × 4.6 mm) with a mobile phase (3/4 dilution of 3.2 mM Bis-Tris, 8 mM p-hydroxybenzoic acid, 50 mM boric acid) and a flow rate of 1.2 ml min-1 at 40°C. Statistical analyses were performed using the Student's t test.
Microcon ym 10 centrifugal filters
The Microcon YM-10 centrifugal filters are a type of laboratory equipment used for sample concentration and buffer exchange. They feature a 10,000 molecular weight cut-off membrane that allows the passage of low molecular weight molecules while retaining larger molecules of interest.
2 protocols using microcon ym 10 centrifugal filters
Quantification of Organic and Inorganic Ions in GCPs
The measurement of organic and inorganic ions was performed on an HPLC (Prominence, Shimadzu). The chromatographic system consisted of a Shimadzu Model system controller (SLC-10AVP), conductivity detector (CDD-10ADVP), and column oven (CTO-20A). K- and Na+ were separated using a LC-10ADVP pump, a column Shim-pack IC-C4 (150 mm × 4.6 mm) and a guard column Shim-pack IC-GC4 (10 mm × 4.6 mm) with a mobile phase (3.2 mM Bis-Tris, 8 mM p-hydroxybenzoic acid, 50 mM Boric acid) and a flow rate of 1.0 ml min-1 at 40°C. Cl- and Malate2- were separated with a LC-20AD pump, a column Shim-pack IC-A3 (150 mm × 4.6 mm) and guard column Shim-pack IC-GA3 (10 mm × 4.6 mm) with a mobile phase (3/4 dilution of 3.2 mM Bis-Tris, 8 mM p-hydroxybenzoic acid, 50 mM boric acid) and a flow rate of 1.2 ml min-1 at 40°C. Statistical analyses were performed using the Student's t test.
Lipid Nanoparticle Formulation and Characterization
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!