The largest database of trusted experimental protocols

Hplc ms ms system 1200l triple quadrupole mass spectrometer

Manufactured by Agilent Technologies

The HPLC–MS/MS system 1200L triple–quadrupole mass spectrometer is a high-performance liquid chromatography tandem mass spectrometry instrument. It combines high-pressure liquid chromatography with a triple-quadrupole mass spectrometer for sensitive and selective detection and quantification of target analytes in complex samples.

Automatically generated - may contain errors

2 protocols using hplc ms ms system 1200l triple quadrupole mass spectrometer

1

LC-MS/MS Analysis of Biomolecules

Check if the same lab product or an alternative is used in the 5 most similar protocols
For LC–MS/MS, a Varian HPLC–MS/MS system 1200L triple–quadrupole mass spectrometer equipped with an electrospray ionization source was used. Analytes were separated in incubation mixtures by HPLC with a Luna C18, 5 μm, 50 mm × 2.1 mm column (Phenomenex) or a Acquity BEH C18, 50*2.1mm, 1,7μm column (Waters). The mobile phase solvents used were 0.1% formic acid in water (A) or 0.1% formic acid in acetonitrile (B) using a gradient: 2–98% B for 2.30 min; hold at 98% B for 1.00 min; 98–2% B for 0.10 min; 2% B hold for 1.50 min. The injection volume was 10 μL, and the flow rate was 0.6 mL·min−1. MS analysis were performed with MRM detection using the parameters optimized for each compounds, with MS Workstation software (version 6.3.0 or higher).
+ Open protocol
+ Expand
2

LC-MS/MS Analytical Protocol for Compound Separation

Check if the same lab product or an alternative is used in the 5 most similar protocols
For LC−MS/MS, a Varian HPLC−MS/MS system 1200L triple−quadrupole mass spectrometer equipped with an electrospray ionization source was used. Analytes were separated in incubation mixtures by HPLC with a Luna C18, 5 μm, 50 mm × 2.1 mm column (Phenomenex) or a Acquity BEH C18, 50 × 2.1 mm, 1, 7 μm column (Waters). The mobile phase solvents used were 0.1% formic acid in water (A) or 0.1% formic acid in acetonitrile (B) using a gradient: 2–98% B for 2.30 min; hold at 98% B for 1.00 min; 98–2% B for 0.10 min; 2% B hold for 1.50 min. The injection volume was 10 μl, and the flow rate was 0.6 ml min−1. MS analysis were performed with MRM detection using the parameters optimized for each compounds, with MS Workstation software (version 6.3.0 or higher).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!