The largest database of trusted experimental protocols

2 protocols using bond elut jr 500 mg spe c18 cartridge

1

Phytochemical Analysis of Plant Extracts

Check if the same lab product or an alternative is used in the 5 most similar protocols
Formic acid (>98% purity), acetonitrile (LC-MS grade), methanol, rutin, quercetin, apigenin and kaempferol were purchased from Merck (Darmstadt, Germany). apigenin 7-O-glucoside, quercetin 3-O-glucoside, kaempferol 3-O-rutinoside and luteolin were purchased from Extrasynthese (Genay Cedex, France). Cynarin, chlorogenic acid, 1,5-dicaffeoylquinic acid, 3,5-dicaffeoylquinic acid, 4,5-dicaffeoylquinic acid, luteolin 7-O-glucuronide, apigenin, 7-O-glucoside, luteolin 7-O-glucoside and diosmetin were purchased from Phytolab (Vestenbergsgreuth, Germany). Bond Elut Jr 500 mg SPE-C18 cartridge was from Agilent (Santa Clara, California, USA). A Milli-Q purification system (Millipore, Bedford, MA, USA) was used to obtain the deionised water (18.2 MΩ cm). All chemicals used for biological assays were obtained as pure commercial products from Sigma Chemical Co (St. Louis, USA) and used without further purification. Spectrophotometric determinations were obtained with an Ultrospec 2100 spectrophotometer (Biochrom Ltd, Cambridge, England) using a 1 cm length path cell.
+ Open protocol
+ Expand
2

Extraction and Purification of Phytochemicals

Check if the same lab product or an alternative is used in the 5 most similar protocols
Two extracts were prepared from each sample; 0.500 g of dried and ground powder was extracted using an ultrasonic bath (Soltec, Sonica S3 EP 2400) operating at 40 KHz with 10 mL of ethanol, 3 times for 10 min each. The supernatants were combined and centrifuged at 5000 rpm for 10 min, poured into a glass balloon, and evaporated in a rotary evaporator under vacuum at a temperature below 50 °C. In order to reduce chlorophyll interference, 30 mg of crude extract were resuspended in 1 mL of methanol/water (20 : 80, v/v), loaded onto a Bond Elut Jr 500 mg SPE-C18 cartridge (Agilent Technologies), eluted with 8 mL of methanol/water (95 : 5, v/v), and evaporated in a rotary evaporator. Pool samples, obtained by mixing the leaves that were harvested in summer (PGSum) and autumn (PGAut), were also created and extracted in the same way.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!