The largest database of trusted experimental protocols

Quantstudio 7 flex real time rcr system

Manufactured by Thermo Fisher Scientific
Sourced in United States

The QuantStudio 7 Flex Real-Time PCR System is a high-performance instrument designed for real-time PCR experiments. It features a flexible block configuration, advanced thermal cycling capabilities, and a user-friendly software interface. The system is capable of performing a wide range of real-time PCR applications, including gene expression analysis, genotyping, and copy number variation studies.

Automatically generated - may contain errors

2 protocols using quantstudio 7 flex real time rcr system

1

miRNA Expression Analysis Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
The total RNA was extracted using the miRNeasy Mini Kit (Qiagen, 217004) with RNase-Free DNase Set (Qiagen, 79254) according to the manufacturer’s instructions. A 10pg of mirVana miRNA mimic miR-199a-5p (ThermoFisher, Assay ID MC10893 and 002304) was added to 0.1–0.5ug of the total RNA as a spike-in control for RT-qPCR normalization. Reverse transcription was performed using PrimeScript™ RT Master Mix (TaKaRa, RR036A) for novel miRNA and TaqMan™ MicroRNA Reverse Transcription Kit (Applied Biosystems, 4366597) for the candidate miRNAs let-7b-5p (ThermoFisher, Assay ID 000378) and miR-34a-5p (ThermoFisher, Assay ID 000426). One microliter of cDNA was used for a real-time PCR using TaqMan™ Universal PCR Master Mix (Applied Biosystems, 4364340) on the ABI QuantStudio 7 Flex Real-Time RCR system. Primers and probes used are listed in the Additional file 5: Table S4. Results were calculated with 2(−ΔΔCt).
+ Open protocol
+ Expand
2

Hepatic Gene Expression Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reverse transcription was performed using total RNA and High Capacity RNA-to-cDNA (Thermo Fisher Scientific, Waltham, MA, USA) according to the manufacturer’s instructions. Gene expression was measured using the QuantStudio 7 flex Real Time RCR System (Applied Biosystems, CA, USA), and the following primer and probe sets were used for the detection of each gene transcript: ALB (Hs00609411_m1), AFP (Hs00173490_m1), CYP1A2 (Hs00167927_m1), CYP2B6 (Hs04183483_g1), CYP2C9 (Hs00426397_m1), CYP2C19 (Hs00426380_m1), CYP2D6 (Hs00164385_m1), CYP2E1 (Hs00559368_m1), CYP3A4 (Hs00430021_m1), CYP7A1 (Hs00167982_m1), FXR (Hs01026590_m1), OATP1B1 (Hs00272374_m1), NTCP (HS00161820_m1), MRP2 (Hs00960489_m1), and BSEP (Hs00994811_m1). Gene expression levels are presented as relative values to the human liver-derived RNA levels (BioChain Institute, Inc., Newark, CA, USA). In addition, the expression level of CYPs in 22 lots of human cryopreserved hepatocytes shown in Table S1 was measured for comparison.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!