The largest database of trusted experimental protocols

5 protocols using dinotefuran

1

Quantitative Analysis of Neonicotinoids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Certified neonicotinoid standards, acetamiprid, clothianidin, dinotefuran, imidacloprid, nitenpyram, thiamethoxam, and thiacloprid, were purchased from FUJIFILM Wako Pure Chemical Corporation. (Osaka, Japan). A standard solution containing ISs of seven neonicotinoids (acetamiprid-d3, clothianidin-d3, dinotefuran-d3, imidacloprid-d4, nitenpyram-d3, thiamethoxam-d3, and thiacloprid-d4), at a concentration of 10 µg/mL in acetonitrile were purchased from Hayashi Pure Chemical Ind. (Osaka, Japan). The chemical structures of the seven neonicotinoid pesticides and their stable isotope-labeled surrogates are shown in Fig. 1. acetonitrile, methanol, and ultrapure water purchased from Wako were of the pesticide-analysis grade and were used for the extraction and cleanup processes during the analysis.
+ Open protocol
+ Expand
2

Quantitative Analysis of Pesticide Residues

Check if the same lab product or an alternative is used in the 5 most similar protocols
Analytical standards of dinotefuran (purity 99.8%), fludioxonil (purity 100%), and pyridalyl (purity 99.2%) were purchased from FUJIFILM Wako Pure Chemical (Japan). Pesticide analysis-grade acetone, acetonitrile, and methanol; LC-MS-grade methanol; and analytical-grade ammonium formate and formic acid were purchased from FUJIFILM Wako Pure Chemical. Water used in the experiments was purified using a PURELAB Flex-UV system (Veolia Water Technologies, France).
Standard stock solutions (200 mg/L) of each pesticide were prepared separately with acetone. An aliquot of the dinotefuran stock solution was diluted with methanol/water (1 : 4, v/v) to prepare standard solutions with concentrations ranging from 0.05 to 2 µg/L. Aliquots of the fludioxonil and pyridalyl stock solutions were mixed and diluted with methanol to prepare standard solutions with concentrations ranging from 0.05 to 2 µg/L. These standard solutions were used for preparing calibration curves.
+ Open protocol
+ Expand
3

Quantitative analysis of neonicotinoids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Acetamiprid, imidacloprid, nitenpyram, thiacloprid, and thiamethoxam were obtained from AccuStandard (New Haven, CT, USA). Clothianidin, dinotefuran, and thiacloprid amide were obtained from Wako Pure Chemical Industries (Osaka, Japan). Desmethyl-Acetamiprid and desmethyl-thiamethoxam were obtained from Sigma-Aldrich (St. Louis, MO, USA). Acetamiprid-d6 was obtained from Hayashi Pure Chemicals (Osaka, Japan). Acetamiprid-d3, Clothianidin-d3, imidacloprid-d4, and thiamethoxam-d4 were obtained from Dr. Ehrenstorfer (Augsburg, Germany). dinotefuran-d3 and thiacloprid-d4 were obtained from @rtMolecule (Poitiers, France) and C/D/N Isotopes (Pointe-Claire, Canada), respectively.
+ Open protocol
+ Expand
4

Pesticide Detection Assay Development

Check if the same lab product or an alternative is used in the 5 most similar protocols
Boscalid, benalaxyl, fenhexamid, tecloftalam, clothianidin, nitenpyram, imidacloprid, dinotefuran, thiacloprid, thiamethoxam were purchased from Wako Pure Chemical Industries, Ltd. (Osaka, Japan). Acetamiprid was purchased from Hayashi Pure Chemical Ind., Ltd. (Osaka, Japan). Bovine serum albumin (BSA: Prod. No. A7888) was purchased from Sigma-Aldrich Co. (St. Louis, MO, USA). Horseradish peroxidase (HRP) was purchased from Toyobo Co., Ltd. (Osaka, Japan). The anti-Boscalid monoclonal antibody (MoAb) was prepared as described previously. 20 The anti-clothianidin MoAb and anti-nitenpyram MoAb were provided from Horiba Ltd. (Kyoto, Japan). 18 All other chemicals and reagents used were of analytical grade, and purchased from Wako Pure Chemical Industries, Ltd. or Nacalai Tesque, Inc. (Kyoto, Japan).
+ Open protocol
+ Expand
5

Quantification of Neonicotinoid Pesticides

Check if the same lab product or an alternative is used in the 5 most similar protocols
We analyzed six compounds, five of which were mother compounds (Acetamiprid, Clothianidin, dinote-furan, imidacloprid, and thiamethoxam) and the other a metabolite (desmethyl-Acetamiprid). imidacloprid currently accounts for approximately 41.5% of the global neonicotinoid market in terms of sales, and this is followed by thiamethoxam (23.8%), Clothianidin (16.7%), and Acetamiprid (10.5%) 12) . dinotefuran accounts for approximately 3% of the global neonicotinoid market 12) . The major neonicotinoid compounds were therefore included in this study.
Acetamiprid, imidacloprid, and thiamethoxam were obtained from AccuStandard (New Haven, CT, USA). Clothianidin and dinotefuran were purchased from Wako Pure Chemical Industries (Osaka, Japan). Desmethyl-Acetamiprid was obtained from Sigma-Aldrich (St. Louis, MO, USA). Isotope-labeled Acetamiprid (Acetamiprid-d6) was purchased from Hayashi Pure Chemical Ind. (Osaka, Japan). Acetamiprid-d3, Clothianidin-d3, imidacloprid-d4, and thiamethoxam-d4 were obtained from Dr. Ehrenstorfer Inc. (Augsburg, Germany). dinotefuran-d3 was purchased from @rtMolecule (Poitiers, France). All reagents were of analytical grade.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now