The largest database of trusted experimental protocols

H14 probe

Manufactured by Büchi

The H14 Probe is a laboratory equipment designed for multi-parameter measurement. It features a compact and robust construction, with integrated sensors to monitor various environmental conditions. The probe provides reliable and accurate data collection for scientific research and analysis applications.

Automatically generated - may contain errors

2 protocols using h14 probe

1

Preparation of LPV SDNs via Emulsion-Spray-Drying

Check if the same lab product or an alternative is used in the 5 most similar protocols
The LPV SDNs were prepared by emulsion-spray-drying as described by Owen et al. 49 Briefly, a stock solution of LPV (200 mg mL -1 in dichloromethane (DCM)), polyvinyl alcohol (PVA grade 4-88, MW 57-77 000) (50 mg mL -1 in water), Kolliphor TPGS (50 mg mL -1 in water) were prepared. Three stock solutions were mixed in the LPV : PVA : Kolliphor TPGS ratio of 60 : 192 : 48 (mL) in a 1 : 4 DCM to water mixture. Emulsification was conducted using a Hielscher UP400S ultrasonic processor equipped with a H14 Probe at 100% output (140 W) for 180 seconds, with immediate spray-drying using a benchtop spray-dryer (BUCHI Mini-290) with an air-atomizing nozzle and compressed air as the drying gas. Spray-drying process conditions: 7 mL min -1 solution flow rate; 65 °C outlet temperature; 110 °C inlet temperature. Resultant powders were further dried under vacuum for 48 hours to remove residual DCM. SDN dispersions result from subsequent powder dispersion in water; for DLS characterisation, powders were dispersed in distilled water at 2 mg mL -1 (1 mg mL -1 cf. LPV).
+ Open protocol
+ Expand
2

Emulsion-Spray-Dried LPV SDNs

Check if the same lab product or an alternative is used in the 5 most similar protocols
The LPV SDNs were prepared by emulsion-spray-drying as described by Giardiello et al. 22 Briefly, a stock solution of LPV (200 mg mL À1 in dichloromethane (DCM)), polyvinyl alcohol (PVA grade 4-88, M W 57-77 000) (50 mg mL À1 in water), Kolliphor TPGS (50 mg mL À1 in water) were prepared. Three stock solutions were mixed in the LPV : PVA : Kolliphor TPGS ratio of 60 : 192 : 48 (mL) in a 1 : 4 DCM to water mixture. Emulsification was conducted using a Hielscher UP400S ultrasonic processor equipped with a H14 Probe at 100% output (140 W) for 180 seconds, with immediate spray-drying using a benchtop spray-dryer (BUCHI Mini-290) with an air-atomizing nozzle and compressed air as the drying gas. Spray-drying process conditions: 7 mL min À1 solution flow rate; 65 1C outlet temperature; 110 1C inlet temperature. Resultant powders were further dried under vacuum for 48 hours to remove residual DCM. SDN dispersions result from subsequent powder dispersion in water; for DLS characterisation, powders were dispersed in distilled water at 2 mg mL À1 (1 mg mL À1 cf. LPV). The LPV SDNs had a Z-average diameter of 330 nm and PdI of 0.18.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!