Scc68

Manufactured by National Instruments
Sourced in United States, United Kingdom

The SCC68 is a data acquisition module from National Instruments. It features 68 digital I/O channels and can be used to interface with a variety of electronic devices and systems. The module provides a flexible and configurable platform for data collection and control applications.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using scc68

1

Electrotactile Noise Stimulation for Sensory Research

Check if the same lab product or an alternative is used in the 5 most similar protocols
Electrotactile non-uniform white noise was applied at the posterior thigh (see Figure 1A) within a frequency band of 0–50 Hz (the band must contain the target frequency of 30 Hz to allow for the resonance effect). Electrical noise was generated with a custom LabVIEW® program and output via a DAQ interface (SCC68, National Instruments, Austin, TX, United States) to a constant current isolated stimulator (A395, World Precision Instruments, Sarasota, FL, United States) through two 34 mm round sensor adhesive electrodes (Ambu® BlueSensor M, Ambu Sdn. Bhd., Penanq, Malaysia) affixed to the skin with Transpore® medical tape on either side of the SR location.
+ Open protocol
+ Expand
2

Vibration Stimulation of FAI Receptors

Check if the same lab product or an alternative is used in the 5 most similar protocols
Vibration at the test site was produced using a probe of 6 mm diameter attached to an electromagnetic vibrator (mini-shaker type 4810, Bruel and Kjaer, Naerum, Denmark), and applied perpendicularly to the skin (see Figure 1A). Vibration frequency was set to 30 Hz to preferentially activate the FAI receptors (Toma and Nakajima, 1995 (link)). The frequency was delivered using a custom program in LabVIEW® and a custom-built BNC breakout box and amplified (Power Amplifier Type 2719, Bruel and Kjaer, Naerum, Denmark). Acceleration and force data were collected (acceleration - model 2221D, Endevco, CA, United States; force – Model 31 load cell, Honeywell, MN, United States) at a sampling frequency of 1000 Hz (BNC-2111, National Instruments, Austin, TX, United States). Displacement of the probe was measured by a custom sensor (model RGH24Z, Renishaw, Gloucestershire, United Kingdom) and input via a DAQ interface (SCC68, National Instruments, Austin, TX, United States) into the custom LabVIEW® program.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!