Superdex 200 prep grade 10 200 gl size exclusion column

Manufactured by GE Healthcare
Sourced in United States

The Superdex 200 prep grade 10/200 GL size exclusion column is a laboratory equipment product designed for biomolecule separation. It is used for the purification and analysis of proteins, peptides, and other macromolecules based on their size and molecular weight.

Automatically generated - may contain errors

2 protocols using superdex 200 prep grade 10 200 gl size exclusion column

1

Size Exclusion Chromatography for Protein Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
A Superdex 200 prep grade 10/200 GL size exclusion column (GE Healthcare, Piscaway, USA) was connected to an Agilent 1100 Series (Agilent Technologies, Santa Clara, USA) and equilibrated with SEC low salt running buffer (50 mM HEPES, pH 7.0) at 1.0 mL/min. 100 μL of sample was injected und absorbance was monitored at 280 nm. The concentration of protein was determined by comparison to a calibration curve prepared from a standard solution of the same protein. The amount of nanoparticle was only determined relatively to the feed.
+ Open protocol
+ Expand
2

Size Exclusion Chromatography Purification

Check if the same lab product or an alternative is used in the 5 most similar protocols
A Superdex 200 prep grade 10/200 GL size exclusion column (GE Healthcare) or a self-packed Sephacryl300 10/200 column (GE Healthcare) was connected to an ÄKTA-explorer system (GE Healthcare) and equilibrated with SEC low salt running buffer (50 mM HEPES, pH 7.0) at 1.0 mL/min. 200 μL or 1000 μL of sample was injected, the absorbance was monitored at 280 nm and the peaks were collected.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!