MRI scanning was performed on a GE × 750 3 T scanner (General Electric, Waukesha, WI, USA) with an eight-channel head coil and parallel imaging with the Array Spatial Sensitivity Encoding Technique. A T1-weighted volume scan was acquired in the axial plane with a 3D fast spoiled gradient-echo sequence using the following parameters: inversion time (TI) = 450 ms; repetition time (TR) = 8.2 ms; echo time (TE) = 3.2 ms; flip angle = 12°; acquisition matrix = 256 mm × 256 mm, field of view (FOV) = 256 mm; slice thickness = 1.0 mm, no gap, yielding a voxel resolution of 1 mm isometric. A 3D T2 FLAIR sequence was acquired in the sagittal plane using the following parameters: TI = 1868 ms; TR = 6000 ms; TE = 123 ms; flip angle = 90°; acquisition matrix = 256 mm × 256 mm, FOV = 256 mm; slice thickness = 2.0 mm, no gap, yielding a voxel resolution of 1 mm × 1 mm × 2 mm. Additional details have been previously described [6 (link), 7 (link)].