Lung CT scans were performed using one of three scanners (128-slice Somatom Definition Edge, Siemens Healthcare; 64-slice Ingenuity, Philips Healthcare; 16-slice GE Brightspeed, GE Medical System) without contrast media injection, with the patient in supine position, during end-inspiration. Scanning parameters were: tube voltage 120 KV, automatic tube current modulation, collimation width 0.625 or 1.25 mm, acquisition slice thickness 2.5 mm, and interval 1.25 mm. Images were reconstructed with a high-resolution algorithm at slice thickness 1.0/1.25 mm. During CT reporting, each radiologist completed both the usual radiology report as well as a structured report, including the presence/absence of GGO and consolidations, and the extension of pulmonary lesions using a visual scoring system (0%, 1–19%, 20–39%, 40–59%, and ≥60% of parenchymal involvement) [25 (link)].