A main limitation of efficiency calibrated method and ΔΔCt method is that only one set of cDNA samples are employed to determine the amplification efficiency. It was assumed that the same amplification efficiency could be applied to other cDNA samples as long as the primers and amplification conditions are the same. However, amplification efficiency not only depends on the primer characteristics, but also varies among different cDNA samples. Using a standard curve for only one set of tested samples to derive the amplification efficiency might overlook the error introduced by sample differences. In our experimental design, we have performed standard curve experiments with four concentrations of three replicates for all samples and genes involved. The ΔΔCt will derive from the standard curves only, and the data quality is examined for each gene and sample combination. The analysis of two samples is presented in the paper as an example. A minimal of PCRs of two replicates in three concentrations will be required for each sample. Even though more effort is required, the data is more reliable out of stringent data quality control and data analysis based on statistical models. The output dataset included Ct number, gene name, sample name, concentration and replicate. We used Microsoft® Excel to open the exported Ct file from an ABI 7000 sequence analysis system and then to transform data into a tab delimited text file for SAS processing. The sample data set is shown in Table 1. All programs were developed with SAS 9.1 (SAS Institute).
Concentrations of cDNA samples (four concentrations of three replicates)
Annotations
Based on most similar protocols
Etiam vel ipsum. Morbi facilisis vestibulum nisl. Praesent cursus laoreet felis. Integer adipiscing pretium orci. Nulla facilisi. Quisque posuere bibendum purus. Nulla quam mauris, cursus eget, convallis ac, molestie non, enim. Aliquam congue. Quisque sagittis nonummy sapien. Proin molestie sem vitae urna. Maecenas lorem.
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to
get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required