Confocal laser scanning microscopy (CLSM) was conducted using a Leica Microsystems Confocal Microscope SP8. For surface-attached biofilms imaging, bacterial cultures were incubated in high content imaging plate (Corning, New York) to form mature biofilms as described above. Afterward, biofilms were washed with sterilized ddH2O twice to remove non-attached aggregates. CLSM images were obtained using a 63×/1.4 OIL objective. Fluorescent excitation was conducted with the argon laser at 488 nm and the emitted fluorescence was acquired at 484–536 and 567–654 nm for GFP and mKate, respectively. Z stack series of biofilms were obtained with 1 μm steps and stacked images were merged using ImageJ software. For frequencies determination of strains in each CLSM image, ImageJ was used to convert the stacks into binary images and the threshold was set above 0. Afterward, the generated stacks were activated using the biofilm selection and the total pixel volumes for each stack were retrieved using the “stacks statistics” function120 (link).
Quantitative Biofilm Imaging Protocol
Confocal laser scanning microscopy (CLSM) was conducted using a Leica Microsystems Confocal Microscope SP8. For surface-attached biofilms imaging, bacterial cultures were incubated in high content imaging plate (Corning, New York) to form mature biofilms as described above. Afterward, biofilms were washed with sterilized ddH2O twice to remove non-attached aggregates. CLSM images were obtained using a 63×/1.4 OIL objective. Fluorescent excitation was conducted with the argon laser at 488 nm and the emitted fluorescence was acquired at 484–536 and 567–654 nm for GFP and mKate, respectively. Z stack series of biofilms were obtained with 1 μm steps and stacked images were merged using ImageJ software. For frequencies determination of strains in each CLSM image, ImageJ was used to convert the stacks into binary images and the threshold was set above 0. Afterward, the generated stacks were activated using the biofilm selection and the total pixel volumes for each stack were retrieved using the “stacks statistics” function120 (link).
Corresponding Organization :
Other organizations : Technical University of Denmark, Institute of Plant Biology
Variable analysis
- Microscopy technique (bright-field microscopy vs. confocal laser scanning microscopy)
- Characteristics of bacterial pellicles and colonies
- Characteristics of surface-attached biofilms
- Axio Zoom V16 stereomicroscope (Carl Zeiss) equipped with a Zeiss CL 9000 LED light source, a PlanApo Z 0.5× objective, and AxioCam 591 MRm monochrome camera (Carl Zeiss, Jena)
- Leica Microsystems Confocal Microscope SP8 with a 63×/1.4 OIL objective
- Fluorescent excitation at 488 nm and emission acquisition at 484–536 and 567–654 nm for GFP and mKate, respectively
- Z-stack series of biofilms obtained with 1 μm steps
- ImageJ software used for image analysis and quantification
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!