Serum total cholesterol, TG, and HDL-cholesterol were measured by enzymatic methods using a commercial kit (Sekisui, Osaka, Japan) with a Hitachi Automatic Analyzer 7600 (Hitachi, Tokyo, Japan). LDL-cholesterol was calculated using the Friedewald formula: LDL-cholesterol = total cholesterol − HDL-cholesterol − (TG/5) [25 (link)]. Non-HDL-cholesterol was calculated by subtracting the quantity of HDL-cholesterol from total cholesterol [26 (link)].
Thyroid and Lipid Biomarker Measurement
Serum total cholesterol, TG, and HDL-cholesterol were measured by enzymatic methods using a commercial kit (Sekisui, Osaka, Japan) with a Hitachi Automatic Analyzer 7600 (Hitachi, Tokyo, Japan). LDL-cholesterol was calculated using the Friedewald formula: LDL-cholesterol = total cholesterol − HDL-cholesterol − (TG/5) [25 (link)]. Non-HDL-cholesterol was calculated by subtracting the quantity of HDL-cholesterol from total cholesterol [26 (link)].
Corresponding Organization : Catholic University of Korea
Other organizations : Seoul St. Mary's Hospital, Incheon St. Mary's Hospital
Variable analysis
- Iodine intake status
- Serum free T4
- Serum TSH
- Serum thyroid peroxidase antibodies (TPOAb)
- Serum total cholesterol
- Serum triglycerides (TG)
- Serum HDL-cholesterol
- Serum LDL-cholesterol
- Serum non-HDL-cholesterol
- Urine iodine concentration
- Participant blood and urine samples
- Electrochemiluminescence immunoassay for measuring serum free T4, TSH, and TPOAb
- E-free T4 kit, E-TSH kit, and E-Anti-TPO kit for measuring free T4, TSH, and TPOAb, respectively
- Reference ranges for free T4 (0.89 to 1.76 ng/mL) and TPOAb (0–34 IU/mL)
- Reference range for serum TSH (0.62 to 6.68 mIU/L) based on population data
- Enzymatic methods using a commercial kit for measuring serum total cholesterol, TG, and HDL-cholesterol
- Friedewald formula for calculating LDL-cholesterol
- Calculation of non-HDL-cholesterol by subtracting HDL-cholesterol from total cholesterol
- Inductively coupled plasma mass spectroscopy (ICP-MS) for measuring urine iodine concentration
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!