Tobacco filler from individual cigarettes was removed from the paper wrapper, 5 mL of 2N NaOH was added to 1.0 grams of tobacco filler in a 60 mL amber vial, followed by extraction with 50 mL of an MTBE stock that contained quinoline as an internal standard. A 1 mL aliquot of the extract was placed in a 2 mL amber vial for GC/MS analysis. The sample preparation and nicotine analytical method have been previously described.13 Five replicates were analyzed for each variety.