1H (500 MHz) and 13C NMR (125 MHz) spectra were recorded on a Bruker Avance Digital 500 spectrometer. Melting points were determined on a microscopic melting point apparatus (Stanford Research Inc. MPA 100 automated melting point apparatus). High-resolution mass data were recorded using electronic ionization (HRMS-EI, magnetic sector-electric sector double focusing mass analyzer) at Korea Basic Science Institute, Daegu Center, Korea. All reactions were carried out in a sealed tube under microwave irradiation (CEM, Discover LabMate) and the reaction temperature was maintained by an external infrared sensor. The products were isolated by TLC (a glass plate coated with Kieselgel 60 GF254, Merck). 2-(2-Bromoaryl)- and 2-(2-bromovinyl)-4,5-diaryl-1H-imidazoles 1 were synthesized from the corresponding aldehydes and 1,2-diarylethane-1,2-diones (see ESI
Synthesis and Characterization of Imidazole Derivatives
1H (500 MHz) and 13C NMR (125 MHz) spectra were recorded on a Bruker Avance Digital 500 spectrometer. Melting points were determined on a microscopic melting point apparatus (Stanford Research Inc. MPA 100 automated melting point apparatus). High-resolution mass data were recorded using electronic ionization (HRMS-EI, magnetic sector-electric sector double focusing mass analyzer) at Korea Basic Science Institute, Daegu Center, Korea. All reactions were carried out in a sealed tube under microwave irradiation (CEM, Discover LabMate) and the reaction temperature was maintained by an external infrared sensor. The products were isolated by TLC (a glass plate coated with Kieselgel 60 GF254, Merck). 2-(2-Bromoaryl)- and 2-(2-bromovinyl)-4,5-diaryl-1H-imidazoles 1 were synthesized from the corresponding aldehydes and 1,2-diarylethane-1,2-diones (see ESI
Partial Protocol Preview
This section provides a glimpse into the protocol.
The remaining content is hidden due to licensing restrictions, but the full text is available at the following link:
Access Free Full Text.
Corresponding Organization : Government of the Republic of Korea
Variable analysis
- Microwave irradiation (CEM, Discover LabMate)
- Reaction temperature maintained by an external infrared sensor
- Melting points
- High-resolution mass data
- NMR spectra (1H at 500 MHz, 13C at 125 MHz)
- Sealed tube
- TLC (a glass plate coated with Kieselgel 60 GF254, Merck) used for product isolation
- Other commercially available organic and inorganic reagents used without further purification
- 2-(2-Bromoaryl)- and 2-(2-bromovinyl)-4,5-diaryl-1
H -imidazoles 1 synthesized from corresponding aldehydes and 1,2-diarylethane-1,2-diones - 2-Aminobenzimidazoles 2 prepared from 1,2-phenylenediamines and cyanogen bromide by known methods
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!