Carbohydrates were determined in water-soluble extract (W-SE) by HPLC analysis. Two grams of freeze-dried fruit powder were extracted with 20 mL of water/perchloric acid (95:5, v:v). In an ice bath, the mixture was sonicated (amplitude 60) with a macro-probe (Vibra-Cell sonicator; Sonic and Materials Inc., Danbury, CT, USA) for 1 min (two cycles, 30 s/cycle, 5 min interval between cycles). The suspension was stirred at room temperature for 1 h, kept at 4 °C overnight, and centrifuged for 10 min at 10,000 rpm. W-SE was filtered and stored at −20 °C until further use. A Spherisorb column (Waters, Milford, CT, USA) and a Perkin Elmer 200a refractive index detector were used to determine the concentrations of glucose, fructose, mannitol, and sucrose [25 (link)]. Carbohydrates standards were purchased from Sigma-Aldrich (Steinheim, Germany).
Comprehensive Fruit Composition Analysis
Carbohydrates were determined in water-soluble extract (W-SE) by HPLC analysis. Two grams of freeze-dried fruit powder were extracted with 20 mL of water/perchloric acid (95:5, v:v). In an ice bath, the mixture was sonicated (amplitude 60) with a macro-probe (Vibra-Cell sonicator; Sonic and Materials Inc., Danbury, CT, USA) for 1 min (two cycles, 30 s/cycle, 5 min interval between cycles). The suspension was stirred at room temperature for 1 h, kept at 4 °C overnight, and centrifuged for 10 min at 10,000 rpm. W-SE was filtered and stored at −20 °C until further use. A Spherisorb column (Waters, Milford, CT, USA) and a Perkin Elmer 200a refractive index detector were used to determine the concentrations of glucose, fructose, mannitol, and sucrose [25 (link)]. Carbohydrates standards were purchased from Sigma-Aldrich (Steinheim, Germany).
Corresponding Organization : Free University of Bozen-Bolzano
Other organizations : University of Bari Aldo Moro
Variable analysis
- Amount of 0.1 M NaOH used to reach a pH of 8.3
- Total titratable acidity (TTA)
- Total proteins
- Fat content
- Dry matter
- Concentrations of glucose, fructose, mannitol, and sucrose
- 10 g of samples homogenized with 90 mL of distilled water using a Stomacher apparatus
- PH measured by a Foodtrode electrode
- Chemical analyses determined by MilkoScan™ FT6000 based on Fourier-transformed infrared technology
- Carbohydrates determined in water-soluble extract (W-SE) by HPLC analysis, including sonication and centrifugation steps
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!