Serum AOPP concentration was measured by spectrophotometry as previously described [44 (link)]. Assays of AOPP in sera were diluted (1:5) in PBS and distributed (200 μL) onto a 96-well plate with 10 μL of 1.16 M potassium iodide. Calibration used a twofold dilution series of chloramine-T solution within a range of 0 to 100 mM. The absorbance was read at 340 nm on a microplate reader (Fusion; PerkinElmer, Wellesley, MA, USA), and AOPP concentration was expressed as mM of chloramine-T equivalents.
Free full text: Click here