In vivo isometric torque produced by hind limb plantar flexor muscles (gastrocnemius, soleus, and other minor muscles) was measured in anesthetized mice at T4 by using the 1300A 3-in-1 Whole Animal Muscle Test System (Aurora Scientific Inc., Aurora, ON, Canada). Inhalation anesthesia (≈3% isoflurane in an induction chamber, then ≈2% isoflurane via nose cone for maintenance, both with 1.5 L/min O2) was delivered by using an anesthetic vaporizer (Harvard Apparatus Fluovac and Datex Ohmeda Isotec 4, Holliston, MA, USA) with an oxygen concentrator (LFY-1-5A, Longfei Group Co., Wenzhou, China; distributed by 2Biological Instruments, Besozzo, VA, Italy). The animal was positioned on a thermostatically controlled plate (36 °C); the right foot was placed on a pedal connected to a servomotor, forming a 90° angle with the secured hind limb. Contractions were elicited with the best stimulus intensity at increasing frequencies (200 ms trains at 1, 10, 30, 50, 80, 100, 120, 150, 180, and 200 Hz), via percutaneous electrical stimulation of the sciatic nerve through a pair of needle electrodes connected to a stimulator. Torque values were calculated with the Dynamic Muscle Analysis software (ASI DMAv5.201) and normalized to mouse body mass (N*mm3/kg). Normalized values were used to construct torque–frequency curves [36 (link),41 (link)].
Comprehensive Neuromuscular Functional Assessment
In vivo isometric torque produced by hind limb plantar flexor muscles (gastrocnemius, soleus, and other minor muscles) was measured in anesthetized mice at T4 by using the 1300A 3-in-1 Whole Animal Muscle Test System (Aurora Scientific Inc., Aurora, ON, Canada). Inhalation anesthesia (≈3% isoflurane in an induction chamber, then ≈2% isoflurane via nose cone for maintenance, both with 1.5 L/min O2) was delivered by using an anesthetic vaporizer (Harvard Apparatus Fluovac and Datex Ohmeda Isotec 4, Holliston, MA, USA) with an oxygen concentrator (LFY-1-5A, Longfei Group Co., Wenzhou, China; distributed by 2Biological Instruments, Besozzo, VA, Italy). The animal was positioned on a thermostatically controlled plate (36 °C); the right foot was placed on a pedal connected to a servomotor, forming a 90° angle with the secured hind limb. Contractions were elicited with the best stimulus intensity at increasing frequencies (200 ms trains at 1, 10, 30, 50, 80, 100, 120, 150, 180, and 200 Hz), via percutaneous electrical stimulation of the sciatic nerve through a pair of needle electrodes connected to a stimulator. Torque values were calculated with the Dynamic Muscle Analysis software (ASI DMAv5.201) and normalized to mouse body mass (N*mm3/kg). Normalized values were used to construct torque–frequency curves [36 (link),41 (link)].
Corresponding Organization : Dompé (Italy)
Protocol cited in 2 other protocols
Variable analysis
- Training phase duration (T0 to T4)
- Forelimb grip strength (absolute and normalized to body mass)
- Total distance run during acute exercise resistance test
- Isometric torque produced by hind limb plantar flexor muscles
- Grip strength measurement protocol
- Treadmill exercise test protocol
- Isometric torque measurement protocol
- Anesthesia administration
- Animal positioning and limb fixation
- Electrical stimulation of the sciatic nerve
- Positive control: None mentioned
- Negative control: None mentioned
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!