We determined NET levels by measuring MPO–DNA complexes with an ELISA as reported earlier [18 (link)]. We adjusted the commercial human cell death ELISA kit (Cell death detection ELISAPLUS, Roche Diagnostics Nederland B.V., Almere, The Netherlands). Briefly, as the capturing antibody, we used anti-MPO monoclonal antibody (clone 4A4, ABD Serotec). Patient plasma was added in combination with the peroxidase-labeled anti-DNA monoclonal antibody (from cell death detection ELISA kit; Roche). The absorbance at 405 nm wavelength was measured using Biotek Synergy HT plate reader with a reference filter of 490 nm. The values are expressed as milli-arbitrary units (mAU/mL).
Quantifying Hemostasis Biomarkers in Plasma
We determined NET levels by measuring MPO–DNA complexes with an ELISA as reported earlier [18 (link)]. We adjusted the commercial human cell death ELISA kit (Cell death detection ELISAPLUS, Roche Diagnostics Nederland B.V., Almere, The Netherlands). Briefly, as the capturing antibody, we used anti-MPO monoclonal antibody (clone 4A4, ABD Serotec). Patient plasma was added in combination with the peroxidase-labeled anti-DNA monoclonal antibody (from cell death detection ELISA kit; Roche). The absorbance at 405 nm wavelength was measured using Biotek Synergy HT plate reader with a reference filter of 490 nm. The values are expressed as milli-arbitrary units (mAU/mL).
Corresponding Organization :
Other organizations : Erasmus MC
Variable analysis
- Fibrinogen levels
- VWF:Ag levels
- ADAMTS13 activity
- Fibrinogen levels
- VWF:Ag levels
- ADAMTS13 activity
- NET levels
- Thromborel S (Behringwerke, Marburg, Germany) on the ACL 300 coagulation analyzer (Instrumentation Laboratory)
- Polyclonal rabbit antihuman VWF antibodies and horseradish-peroxidase-conjugated antihuman VWF antibodies (DakoCytomation, Glostrup, Denmark)
- Fluorescence Resonance Energy Transfer Substrate VWF 73 (FRETS-VWF73)
- Anti-MPO monoclonal antibody (clone 4A4, ABD Serotec)
- Peroxidase-labeled anti-DNA monoclonal antibody (from cell death detection ELISA kit; Roche)
- Biotek Synergy HT plate reader with a reference filter of 490 nm
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!