Echocardiography and hemodynamic measurements were performed at the indicated times after the mice were anesthetized using 1.5–2% isoflurane3 (link)5 (link)6 (link)22 (link)37 (link)44 (link)45 (link). For echocardiography, M-mode images derived from the short axis of the LV were recorded using a Mylab30CV (ESAOTE) machine with a 15-MHz probe. To measure the LVEDD, LVESD and LVFS (LVFS (%)=(LVEDD-LVESD)/LVEDD × 100%), M-mode measurements of the LV internal diameter were obtained from at least three beats and then averaged. Cardiac catheterization studies were performed using a 1.4-French Millar catheter-tip micromanometer catheter (SPR-839; Millar Instruments), which was inserted through the right carotid artery into the left ventricle. The pressure and dp/dt were recorded continuously with an Aria pressure-volume conductance system coupled to a Powerlab/4SP A/D converter and were stored and displayed on a personal computer.