To further reduce false positives and miscalled germline events, we employ a panel of normal samples as a filter. To create this filter we run MuTect on a set of normals as if they were tumors without a matched normal in STD mode. From this data, a VCF file is created for the sites that were identified as variant by MuTect in more than one normal. This VCF is then supplied to the caller, which rejects these sites. However, if the site was present in the supplied VCF of known mutations (--cosmic) it is retained because these sites could represent known recurrent somatic mutations which have been detected in the panel of normal when the normal are from adjacent tissue or have some contamination tumor DNA. The more normal samples used to construct this panel, the higher the power will be to detect and remove rare artifacts. Therefore, we typically we use all the normal samples readily available. The results presented here were obtained by using a panel of whole genome sequencing data from blood normals of 125 solid tumor cancer patients. The samples used as part of the virtual tumor approach were not included in this panel.
Partial Protocol Preview
This section provides a glimpse into the protocol. The remaining content is hidden due to licensing restrictions, but the full text is available at the following link:
Access Free Full Text.
Cibulskis K., Lawrence M.S., Carter S.L., Sivachenko A., Jaffe D., Sougnez C., Gabriel S., Meyerson M., Lander E.S, & Getz G. (2013). Sensitive detection of somatic point mutations in impure and heterogeneous cancer samples. Nature biotechnology, 31(3), 213-219.
Publication 2013
Cancer Cancer blood Cosmic Germline MutationsPatients Somatic Tissue Tumor Tumor dna
Corresponding Organization :
Other organizations :
Broad Institute, Harvard University, Center for Systems Biology, Massachusetts Institute of Technology, Massachusetts General Hospital
MuTect on a set of normals as if they were tumors without a matched normal in STD mode
dependent variables
Sites identified as variant by MuTect in more than one normal
control variables
Panel of normal samples
positive controls
Sites present in the supplied VCF of known mutations (--cosmic)
negative controls
None explicitly mentioned
Annotations
Based on most similar protocols
Etiam vel ipsum. Morbi facilisis vestibulum nisl. Praesent cursus laoreet felis. Integer adipiscing pretium orci. Nulla facilisi. Quisque posuere bibendum purus. Nulla quam mauris, cursus eget, convallis ac, molestie non, enim. Aliquam congue. Quisque sagittis nonummy sapien. Proin molestie sem vitae urna. Maecenas lorem.
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to
get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required