Compounds were isolated by means of open column chromatography (CC). Analytical TLC was carried out on precoated silica gel 60F254 plates (Merck, Darmstadt, Germany). The isolation procedures and purity of compounds were checked by thin layer chromatography (TLC), visualized by means of UV light, and sprayed with Ce(SO4)2 2(NH4)2SO4 2H2O. All 1H- and 13C-, DEPT and 2D NMR experiments (COSY, HSQC and HMBC) were recorded on a Bruker AVANCE III HD 500 MHz at 500 and 125 MHz, respectively, using CDCl3 with tetramethylsilane (TMS) as internal standard. Mass spectrometry in positive ion mode FABMS was performed using a JEOL JMX-AX505HA mass spectrometer. Optical rotations were measured on a 241 digital polarimeter at 25 °C (Perkin Elmer, Waltham, MA, USA) equipped with a sodium lamp (589 nm) and a microcell. Indomethacin (indo), dimethyl sulfoxide (DMSO), etoposide, lipopolysaccharide (LPS) from Escherichia coli serotype 055:B5, sodium nitrite (NaNO2), phosphoric acid (H3PO4), N-(1-naphtyl) ethylenediamine dihydrochloride, sulfanilamide and ursolic acid were purchased from Sigma Aldrich (Mexico City, Mexico). ADVANCED DMEM/F12 (Dulbecco’s Modified Eagle Medium/Ham’s F-12), DMEM/F12 (Dulbecco’s Modified Eagle’s Medium/Nutrient Mixture F-12), fetal bovine serum (FBS) and Glutamine (GlutaMax) were from GIBCO (Waltham, MA USA). MycoZapMT Plus-CL antibiotic was from Lonza (Allendale, NJ, USA). [3-(4,5-dimethyl-2-yl)-5-(3-carboxymethoxyphenyl)-2-(4-sulfophenyl)-2H-tetrazolium, inner salt; MTS] was from Promega Co (Fitchburg, WI, USA). IL-6 and TNF-α kit was from PEPROTECH (Mexico City, Mexico). QUANTI-BlueMT and Zeocin were from InvivoGen (San Diego, CA, USA). Murine macrophage cell line RAW 264.7 (Tib-71TM) was from ATCC® (Georgetown, Washington, DC, USA) and RAW-BlueTM was from InvivoGen. Compounds 5 and 7 were quantified using an HP Agilent Technologies 6890 gas chromatograph equipped with a MSD 5973 quadrupole mass detector (HP Agilent), equipped with a capillary column HP-5MS (length: 30 m; inside diameter: 0.25 mm; film thickness: 0.25 µM). The helium carrier gas was set to the column (1 mL per minute at constant flow). The inlet temperature was set at 250 °C while oven temperature was initially at 40 °C (held for 1 min) and increased to 280 at 10 °C/min. The mass spectrometer was operated in positive electron impact mode with ionization energy of 70 eV. Detection was performed in selective ion-monitoring (SIM) mode and peaks were identified and quantitated using target ions.
Free full text: Click here