We made tissue microarrays (TMAs) of the breast tissue samples [12 (link)]. As described, the tissue cores were punched from donor blocks with a 1-mm-diameter stylus and loaded to recipient paraffin blocks. The design of the TMAs made it possible to evaluate the frequency of markers across tumor grades and molecular subtypes from patient tumors. The TMA layout on the recipient TMA blocks was designed in advance to include duplicates of each tissue sample and to organize the tissue samples randomly across the TMAs. Tissue regions were selected and included in the TMA based on the pathology of the tissue determined from the H&E-stained slides of each tissue block. The TMA blocks were constructed with a Veridiam Advanced Tissue Arrayer VTA-110CC. Blocks were sectioned at 3 μm thickness with Leica rotary microtome RM2125. Each of the two TMAs used for the staining had ~100 tissues per block with duplicates of each tissue sample included across the two TMAs.
For breast cancer tissue TMAs, including two or more tissue punches of 1-mm core diameter is preferred over a single punch or larger punch are more consistent and representative of the entire tumor [17 , 18 (link)].