Automated Production of 18F-FDG and 68Ga-FAPI
Corresponding Organization :
Other organizations : Fudan University Shanghai Cancer Center, Fudan University, Shanghai Medical College of Fudan University, First Affiliated Hospital of Harbin Medical University, Harbin Medical University, National Institute of Environmental Health Sciences
Variable analysis
- Use of the Explora FDG4 module with a cyclotron (CTI RDS Eclipse ST, Siemens, Knoxville, Tennessee, USA) to automatically produce 18F-FDG
- Radiolabeling of DOTA-FAPI-04 with 68Ga according to the protocol published by Lindner et al.
- Radiochemical purity of FDG
- Radiochemical purity of FAPI
- PH maintained at approximately 4.5 during the radiolabeling of DOTA-FAPI-04 with 68Ga
- Heating the mixture of DOTA-FAPI-04 and 68Ga solution at 100°C for 10 minutes
- DOTA-FAPI-04 obtained commercially (Jiangsu Huayi Technology Co. Ltd.)
- 68Ga solution eluted from 68Ge/68Ga generator (IGG100, Eckert & Ziegler)
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!