These kit companies in their kit catalogs stated that the minimum detection limit of subfatin was 0.042 ng/mL. The intra-assay and inter-assay coefficients of variation for plasma subfatin were < 10% and < 12%, respectively. The minimum detection limit of preptin was 5.125 ng/L (0.0051 ng/mL). The intra-assay and inter-assay coefficients of variation for plasma preptin were < 10% and < 12%, respectively. The minimum detection limit of betatrophin was 7.334 ng/L (0.0073 ng/mL). The intra-assay and inter-assay coefficients of variation for plasma betatrophin were < 10% and < 15%, respectively. Preptin and betatrophin concentration units are given in ng/L and subfatin in ng/mL by the manufacturer. However, to facilitate the comparison between parameters, all units were converted to ng/mL [20 (link)].
Plasma Peptide Levels Measurement
These kit companies in their kit catalogs stated that the minimum detection limit of subfatin was 0.042 ng/mL. The intra-assay and inter-assay coefficients of variation for plasma subfatin were < 10% and < 12%, respectively. The minimum detection limit of preptin was 5.125 ng/L (0.0051 ng/mL). The intra-assay and inter-assay coefficients of variation for plasma preptin were < 10% and < 12%, respectively. The minimum detection limit of betatrophin was 7.334 ng/L (0.0073 ng/mL). The intra-assay and inter-assay coefficients of variation for plasma betatrophin were < 10% and < 15%, respectively. Preptin and betatrophin concentration units are given in ng/L and subfatin in ng/mL by the manufacturer. However, to facilitate the comparison between parameters, all units were converted to ng/mL [20 (link)].
Corresponding Organization : Fırat University
Other organizations : Elazığ Eğitim ve Araştırma Hastanesi, Sağlık Bilimleri Üniversitesi
Variable analysis
- Not explicitly mentioned
- Plasma subfatin levels
- Plasma preptin levels
- Plasma betatrophin levels
- Measurement of absorbance using a Chromate 4300 Microplate Reader
- Use of the Human subfatin, preptin, betatrophin ELISA Kit (Sunred Biological Technology, Shanghai, China)
- Use of a plate-washing -incubation CombiWash device (Human Diagnostics, Wiesbaden, Germany)
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!