Unless otherwise specified, all compounds were manipulated using a glovebox or standard Schlenk line techniques with an N2 atmosphere. Anhydrous tetrahydrofuran (THF) was purchased from Aldrich in 18 L Pure-Pac™ containers. Anhydrous benzene, dichloromethane, and diethyl ether were purified by sparging with nitrogen for 15 minutes and then passing under nitrogen pressure through a column of activated A2 alumina (Zapp’s). Methylene chloride-d2 and acetonitrile-d3 were purchased from Cambridge Isotopes, dried over calcium hydride, and vacuum transferred prior to use. Benzene-d6 was also purchased from Cambridge Isotope Laboratories, Inc., dried over sodium/benzophenone ketyl, and vacuum transferred prior to use. Unless indicated otherwise, all commercial chemicals were used as received. LMn3(OAc)3,52 (link)[MnIV3ScO4],40 (link)[MnIV3GdO4],39 (link)[MnIIIMnIV2GdO4],39 (link)[MnIII3CaO(OH)], [MnIIMnIII2YO(OH)], [MnIIMnIII2CaO(OH)],43 (link)[FeIII3LaO(OH)], [FeIII3CaO(OH)], [FeIIFeIII2ScO(OH)], [FeIIFeIII2LaO(OH)], and [FeIIFeIII2CaO(OH)]42 (link) were prepared according to previously published protocols. 1H and 31P NMR spectra were recorded on a Varian Mercury 300 spectrometer at room temperature. Elemental analyses were performed by Robertson Microlit Laboratories, Ledgewood, NJ.