An Ultrasound Microphone (Avisoft UltraSoundGate condenser microphone capsule CM16, Avisoft Bioacoustics, Berlin, Germany) sensitive to frequencies of 10–180 kHz, recorded the pup vocalizations in the sound-attenuating chamber. The microphone was placed through a hole in the middle of the cover of the styrofoam sound-attenuating box, about 20 cm above the pup in its plastic container. The temperature of the room was maintained at 22±1°C. Vocalizations were recorded using Avisoft Recorder software (Version 3.2). Settings included sampling rate at 250 kHz; format 16 bit. For acoustical analysis, recordings were transferred to Avisoft SASLab Pro (Version 4.40) and a fast Fourier transformation (FFT) was conducted. Spectrograms were generated with an FFT-length of 1024 points and a time window overlap of 75% (100% Frame, Hamming window). The spectrogram was produced at a frequency resolution of 488 Hz and a time resolution of 1 ms. A lower cut-off frequency of 15 kHz was used to reduce background noise outside the relevant frequency band to 0 dB. Call detection was provided by an automatic threshold-based algorithm and a hold-time mechanism (hold time: 0.01 s). An experienced user checked the accuracy of call detection, and obtained a 100% concordance between automated and observational detection. Parameters analyzed for each test day included number of calls, duration of calls, qualitative and quantitative analyses of sound frequencies measured in terms of frequency and amplitude at the maximum of the spectrum.
Waveform patterns of calls were examined in depth in twenty sonograms collected from every strain, one from each of the pups tested. The sonograms were one minute in length and selected from recordings at postnatal day 8. We classified 3633 BTBR calls, 2333 B6 calls, 1806 129X1 calls and 2575 FVB/NJ calls. Each call was identified as one of 10 distinct categories, based on internal pitch changes, lengths and shapes, using previously published categorizations [21] (link), [22] (link), [24] (link). Classification of USVs included ten waveform patterns described below, and illustrated visually in
Inter-rater reliability in scoring the call categories was 98%. Call category data were subjected to two different analyses: a) strain-dependent effects on the frequency and duration of the vocalizations emitted by each subject at pnd 8 b) strain-dependent effects on the probability of producing calls from each of the ten categories of USV, as described below under Statistical analysis.