Single‐slice transverse CT images at L1 and L3 were determined to quantify skeletal muscle mass and quality. 18 (link) CT scanners from General Electric (GE) (128‐slice spiral CT scanners from GE discovery CT, 128‐slice spiral CT scanners from GE optima CT660, and 256‐slice spiral CT scanners from GE revolution CT) and Siemens (64‐slice spiral CT scanners from SOMATOM sensation CT, SOMATOM definition flash CT, and SOMATOM definition AS CT, and 96‐slice spiral CT scanners from SOMATOM force CT) were used. Image analysis was conducted with ImageJ (version 1.46). 19 (link) The value of HU represents the radiodensity. Tissues were measured by using a threshold for HU of −29 to +150 for skeletal muscle 20 (link) (FigureS1). The mean radiodensity of the whole muscle area at the L1 and L3 cross‐sectional areas was selected for analysis of SMD (indicator used to quantify skeletal muscle quality, HU). SMI (cm2/m2) was represented by the skeletal muscle area corrected by body height squared. 21 (link)
Sheng M., Cao J., Hou S., Li M., Wang Y., Fang Q., Miao A., Yang M., Liu S., Hu C., Liu C., Wang S., Zheng J., Xiao J., Zhang X., Liu H., Liu B, & Wang B. (2023). Computed tomography‐determined skeletal muscle density predicts 3‐year mortality in initial‐dialysis patients in China. Journal of Cachexia, Sarcopenia and Muscle, 14(6), 2569-2578.
Corresponding Organization : Zhongda Hospital Southeast University
Other organizations :
Jiangsu University, First People's Hospital of Kunshan, Nanjing Medical University, Nantong University, Taizhou People's Hospital, The First People's Hospital of Changzhou, Yangzhou University, Southeast University, Covenant Health
Type of CT scanner (128-slice spiral CT scanners from GE discovery CT, 128-slice spiral CT scanners from GE optima CT660, 256-slice spiral CT scanners from GE revolution CT, 64-slice spiral CT scanners from SOMATOM sensation CT, SOMATOM definition flash CT, SOMATOM definition AS CT, and 96-slice spiral CT scanners from SOMATOM force CT)
dependent variables
Skeletal muscle mass (SMI, cm^2/m^2)
Skeletal muscle quality (SMD, HU)
control variables
CT image analysis using ImageJ (version 1.46)
Threshold for HU of -29 to +150 for skeletal muscle
Annotations
Based on most similar protocols
Etiam vel ipsum. Morbi facilisis vestibulum nisl. Praesent cursus laoreet felis. Integer adipiscing pretium orci. Nulla facilisi. Quisque posuere bibendum purus. Nulla quam mauris, cursus eget, convallis ac, molestie non, enim. Aliquam congue. Quisque sagittis nonummy sapien. Proin molestie sem vitae urna. Maecenas lorem.
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to
get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required