Cardiac action potential recording protocol
Corresponding Organization :
Other organizations : National Heart Centre Singapore, Jinan University, Institute of Molecular and Cell Biology, Bioprocessing Technology Institute, Agency for Science, Technology and Research, Duke-NUS Medical School
Variable analysis
- None explicitly mentioned
- APD at 30%, 50% and 90% of repolarization (APD30, APD50, and APD90)
- Action potential amplitude (APA)
- Maximum diastolic potential (MDP)
- Beating frequency
- Normal Tyrode's solution containing (in mM): NaCl 140, KCl 5.4, CaCl2 1.8, MgCl2 1, glucose 10, HEPES 10, adjusted to pH 7.4 with NaOH
- Pipette solution containing (in mM): KCl 130, NaCl 5, MgCl2 1, MgATP 3, EGTA 10, and HEPES 10, adjusted to pH 7.2 with KOH
- Cells maintained at 35 °C by a temperature controller during the recording of action potentials
- Positive control: None mentioned
- Negative control: None mentioned
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!