To measure fluorescence intensity of AIPL-1::GFP, live worms were mounted and immobilized with 25% Pluronic F-127 (catalog # 2730-50G, Biovision, Milpitas, CA) in M9 buffer containing 0.5 mM levamisole and 0.1% tricaine methanesulfonate. Fluorescence images were captured with the same settings for all samples in NIS-Elements using a Nikon Eclipse TE2000 inverted microscope with a CFI Plan Fluor ELWD 40 × (NA 0.60) objective. Fluorescence intensity of each worm was determined using ImageJ as average fluorescence intensity at 10 randomly selected points within the cytoplasm of the body wall muscle in the head region.
Quantitative Analysis of AIPL-1::GFP Fluorescence in Worms
To measure fluorescence intensity of AIPL-1::GFP, live worms were mounted and immobilized with 25% Pluronic F-127 (catalog # 2730-50G, Biovision, Milpitas, CA) in M9 buffer containing 0.5 mM levamisole and 0.1% tricaine methanesulfonate. Fluorescence images were captured with the same settings for all samples in NIS-Elements using a Nikon Eclipse TE2000 inverted microscope with a CFI Plan Fluor ELWD 40 × (NA 0.60) objective. Fluorescence intensity of each worm was determined using ImageJ as average fluorescence intensity at 10 randomly selected points within the cytoplasm of the body wall muscle in the head region.
Corresponding Organization : Emory University
Other organizations : Simon Fraser University
Variable analysis
- Staining of worms with tetramethylrhodamine-phalloidin
- Fluorescence intensity of AIPL-1::GFP
- Immobilization of live worms with 25% Pluronic F-127 in M9 buffer containing 0.5 mM levamisole and 0.1% tricaine methanesulfonate
- Fluorescence image capture settings
- Positive control: Not explicitly mentioned.
- Negative control: Not explicitly mentioned.
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!