Baseline blood samples were frozen at −80°C and stored for later analysis. 25(OH)D, serum calcium, albumin, and levels of parathyroid hormone (PTH) were measured in the Massachusetts General Hospital (MGH) clinical laboratories. 25(OH)D2 and 25(OH)D3 levels were measured by liquid chromatography–tandem mass spectrometry (LC-MS), with interassay coefficients of variation (CVs) of 9.1% for 25(OH)D2 and 8.6% for 25(OH)D3. Total 25(OH)D level was calculated as the sum of 25(OH)D2 level and 25(OH)D3 level. Intact PTH was measured by electrochemiluminescense immunoassay on the Cobas E160 automated analyzer (Roche Diagnostics, Indianapolis, IN, USA). The interassay CV for intact PTH measurement was 4.2%. Calcium and albumin levels were measured by dye-based photometric assays on an automated analyzer. DBP was measured in duplicate by commercial enzyme-linked immunosorbent assay (ELISA; Cat. No. DVDBP0, R&D Systems, Minneapolis, MN, USA) according to the manufacturer's instructions. The assay was conducted after diluting serum samples 1:2000 in Calibrator Diluent RD6-11 (Part No. 895489, R&D Systems). The interassay CV was 8.5% at a concentration of 40 µg/mL. The assay recovered between 93% and 110% of a 100- to 200-µg/mL dose of exogenous DBP added to human serum samples containing between 25 and 200 µg/mL of endogenous DBP. The manufacturer reports no significant cross-reactivity with human albumin, vitamin D3, or α-fetoprotein. In a subset of patients in whom adequate serum was available (n = 45), total 1,25(OH)2D3 was measured by LC-MS/MS in the Mayo Clinic Medical Laboratories (Rochester, MN, USA).
Powe C.E., Ricciardi C., Berg A.H., Erdenesanaa D., Collerone G., Ankers E., Wenger J., Karumanchi S.A., Thadhani R, & Bhan I. (2011). Vitamin D–Binding Protein Modifies the Vitamin D–Bone Mineral Density Relationship. Journal of Bone and Mineral Research, 26(7), 1609-1616.
Other organizations :
Massachusetts General Hospital, Harvard University, Massachusetts Institute of Technology, Beth Israel Deaconess Medical Center, Howard Hughes Medical Institute
25(OH)D2 and 25(OH)D3 levels measured by liquid chromatography–tandem mass spectrometry (LC-MS)
Intact PTH measured by electrochemiluminescense immunoassay
Calcium and albumin levels measured by dye-based photometric assays
DBP measured by commercial enzyme-linked immunosorbent assay (ELISA)
dependent variables
25(OH)D levels
Serum calcium levels
Albumin levels
Parathyroid hormone (PTH) levels
Total 1,25(OH)2D3 measured by LC-MS/MS
control variables
Baseline blood samples were frozen at −80°C and stored for later analysis
controls
Positive control: Exogenous DBP added to human serum samples
Negative control: No significant cross-reactivity with human albumin, vitamin D3, or α-fetoprotein
Annotations
Based on most similar protocols
Etiam vel ipsum. Morbi facilisis vestibulum nisl. Praesent cursus laoreet felis. Integer adipiscing pretium orci. Nulla facilisi. Quisque posuere bibendum purus. Nulla quam mauris, cursus eget, convallis ac, molestie non, enim. Aliquam congue. Quisque sagittis nonummy sapien. Proin molestie sem vitae urna. Maecenas lorem.
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to
get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required