Cell culture supernatants along with relevant standards were undergone extraction and samples were analyzed by LC-MS using a Shimadzu Nexera UHPLC (Shimadzu North America, Columbia, MD) interfaced to a Q-Exactive Plus ion trap mass spectrometer with a HESI source (ThermoFisher Scientific, San Jose, CA). Chromatographic separations were achieved by employing a 2.1 x 100 mm, 1.8 μm, Acquity HSS T3 column (Waters, Milford, MA) with gradient elution at 0.45 mL/min [20 (link)]. PGE2 was quantified against PGE2-d9 internal standard. The standard curve was generated using a constant concentration of PGE2-d9 (50 pg on column) and variable concentrations of PGE2 (2 pg to 10 ng on column). Peak areas for LC-MS quantification of PGE2 and PGE2-d9 were calculated using Xcalibur QuanBrowser software (ThermoFisher Scientific, San Jose, CA). The coefficient of determination for the standard curve (R2) was 0.9996.
Quantitative Analysis of Prostaglandins
Cell culture supernatants along with relevant standards were undergone extraction and samples were analyzed by LC-MS using a Shimadzu Nexera UHPLC (Shimadzu North America, Columbia, MD) interfaced to a Q-Exactive Plus ion trap mass spectrometer with a HESI source (ThermoFisher Scientific, San Jose, CA). Chromatographic separations were achieved by employing a 2.1 x 100 mm, 1.8 μm, Acquity HSS T3 column (Waters, Milford, MA) with gradient elution at 0.45 mL/min [20 (link)]. PGE2 was quantified against PGE2-d9 internal standard. The standard curve was generated using a constant concentration of PGE2-d9 (50 pg on column) and variable concentrations of PGE2 (2 pg to 10 ng on column). Peak areas for LC-MS quantification of PGE2 and PGE2-d9 were calculated using Xcalibur QuanBrowser software (ThermoFisher Scientific, San Jose, CA). The coefficient of determination for the standard curve (R2) was 0.9996.
Variable analysis
- Concentration of PGE2 analytical standard
- Concentration of PGE2 in cell culture supernatants
- Concentration of PGE2-d9 internal standard (50 pg on column)
- Chromatographic separation using a 2.1 x 100 mm, 1.8 μm, Acquity HSS T3 column with gradient elution at 0.45 mL/min
- LC-MS analysis using a Shimadzu Nexera UHPLC interfaced to a Q-Exactive Plus ion trap mass spectrometer with a HESI source
- PGE2 analytical standard
- PGE2-d9 internal standard
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!