α-galactosylceramide
(α-Galcer) was purchased from Cayman Chemical. Poly(D, L- lactide-co-glycolide
(a mole ratio of 50:50, RESOMER RG 502 H, PLGA), Ovalbumin, Sephadex
G50, Dulbecco’s phosphate buffered saline (PBS), dialysis kit
Pur-A-Lyzer Maxi-6000 MWCO 6–8 kDa, and Amicon Ultra-4 Centrifugal
filter unit were all purchased from Sigma-Aldrich. Ovalbumin Alexa-Fluor
488 and Ovalbumin Alexa-Fluor 647 were purchased from Thermo Fischer
Scientific. Human IFN-γ uncoated ELISA and Mouse IL-2 Uncoated
ELISA kits were purchased from Invitrogen. Solvents were purchased
from Lachner and dried over molecular sieves (3 Å). The block
copolymers poly[N-(2-hydroxypropyl)methacrylamide]-b-poly[N-(4-isopropylphenylacetamide)ethyl
methacrylate] (PHPMA25-b-NR33, herein named NR block), poly[N-(2-hydroxypropyl)methacrylamide]-b-poly[N-(4-ethylamino]carbonyloxymethyl)
phenylboronic acid pinacol ester methacrylate] (PHPMA25-b-MRE30, herein named MRE block), and
poly[N-(2-hydroxypropyl)methacrylamide]-b-poly[N-(4-isopropylamino]carbonyloxymethyl) phenylboronic
acid pinacol ester methacrylate] (PHPMA25-b-MRI26, herein named MRI block) were synthesized as previously
described.23 (link) The block copolymer poly[N-(2-hydroxypropyl)methacrylamide]-b-poly[4-(4,4,5,5-tetra-methyl-1,3,2-dioxaborolan-2-yl)benzyl
methacrylate] (PHPMA37-b-ROS42, herein named ROS block) and the block copolymer poly([N-(2-hydroxypropyl)] methacrylamide)-b-poly[2-(diisopropylamino)ethyl
methacrylate] (PHPMA35-b-PDPA75, herein named pH block) were synthesized according to our previously
reported synthetic pathways.24 (link),25 (link) The subscripts refer
to the degrees of polymerization of each block, as determined by 1H NMR. Table S1 reveals the polymer
block physicochemical characteristics.
Free full text: Click here