In situ muscle force measurements were performed, as previously described [12 (link)]. Briefly, a nonsurvival surgery was performed to expose the left gastrocnemius muscle and calcaneal tendon, the latter of which was cut and attached via silk suture to the force lever arm and the leg stabilized by inserting a disposable monopolar needle (902-DMF37-S, Natus Neurology, WI, USA) through the knee joint. Twitch and tetanic force were recorded following stimulation of the sciatic nerve with 200 ms square pulses via insulated monopolar needles (F-E2M-48, Grass Technologies, RI, USA). A high-speed servo motor-based apparatus (Model 305C, Aurora Scientific, ON, Canada) was used to measure force output. Stimulation current and resting tension were adjusted to maximize twitch force produced by a single stimulus pulse. All subsequent isometric tetanic force data were collected at this stimulation current and resting tension. Isometric force frequency relationship was recorded after stimulation by a train of square wave stimuli and maximum isometric tetanic force was recorded. Animals were then euthanized.
In Situ Muscle Force Measurement
In situ muscle force measurements were performed, as previously described [12 (link)]. Briefly, a nonsurvival surgery was performed to expose the left gastrocnemius muscle and calcaneal tendon, the latter of which was cut and attached via silk suture to the force lever arm and the leg stabilized by inserting a disposable monopolar needle (902-DMF37-S, Natus Neurology, WI, USA) through the knee joint. Twitch and tetanic force were recorded following stimulation of the sciatic nerve with 200 ms square pulses via insulated monopolar needles (F-E2M-48, Grass Technologies, RI, USA). A high-speed servo motor-based apparatus (Model 305C, Aurora Scientific, ON, Canada) was used to measure force output. Stimulation current and resting tension were adjusted to maximize twitch force produced by a single stimulus pulse. All subsequent isometric tetanic force data were collected at this stimulation current and resting tension. Isometric force frequency relationship was recorded after stimulation by a train of square wave stimuli and maximum isometric tetanic force was recorded. Animals were then euthanized.
Variable analysis
- Stimulation current
- Resting tension
- Twitch force
- Tetanic force
- Isometric force frequency relationship
- Maximum isometric tetanic force
- Monopolar needle through the knee joint
- Stimulation of the sciatic nerve
- 200 ms square pulses via insulated monopolar needles
- Positive control: Stimulation of the sciatic nerve to elicit muscle force measurements.
- Negative control: Not explicitly mentioned.
Annotations
Based on most similar protocols
As authors may omit details in methods from publication, our AI will look for missing critical information across the 5 most similar protocols.
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!