A modified Bruker Vertex 70 is used for FTPS EQE spectra. The device was connected with the current amplifier (SR570) to amplify the signal from the device. The data is calibrated with the standard Si and Ge detector. SR303i spectrometer is used to measure the EL. The spectrometer is attached with the newton EMCCD-Si and iDus InGaAs array detector. During the measurement, EMCCD was kept at −40 °C and InGaAs detector kept at −60 °C. The bias of the EL measurement was applied on the devices using a Keithley 2400 Source Meter. The spectrum was calibrated with the standard light source. EQEEL values were obtained from an in-house-built system including a Hamamatsu silicon photodiode 1010B, a Keithley 2400 Source Meter to provide voltage and injected current, and a Keithley 485 Picoammeter to measure the emitted light intensity.