A 7.5 MHz ultrasound probe (LOGIQ P6, General Electric Healthcare, Wauwatosa, WI, USA) was used to measure CSA, MT, FL, and PA of the vastus lateralis (VL). Measurements were taken in a standing position as described by Wagle et al. [49 (link)], as this position has been shown to correlate better with both isometric and dynamic performance. The tester identified and marked 50% of the distance between the greater trochanter and the lateral epicondyle of the right leg. Three MT images were then taken five centimeters anteromedial to the mid-femur mark. The best image from the three was selected for analysis, and the mean of three MT and PA measurements was taken from the first, second, and third portions of the image. Three CSA images were attained by using a panoramic image sweep perpendicular to the VL muscle at the mid-femur mark. CSA was then determined by selecting two out of the three images that best displayed the region of interest and using an image processing software (ImageJ 1.52a, National Institutes of Health, Bethesda, MD, USA) to trace the intermuscular area (Figure 3a). Lastly, FL was estimated by calculating MT∙sin(PA)−1 (Figure 3b). The US technician remained the same throughout all five testing sessions, and all images were analyzed by a single researcher on the same computer.