Sulfur and Li2S at a molar ratio of 5:1 were dissolved in a mixture of 1,2-dimethoxyethane (DME)/1,3-dioxolane (DOL) solution containing 1.0 mol L−1 LiTFSI and 2 wt% LiNO3 to prepare Li2S6 electrolyte. Symmetric cells were assembled by applying CP/Cu-2 as the working and counter electrodes, and the Li2S6 electrolyte usage was 20 μL. CV tests were conducted between –1 and 1 V at the scan rates of 50 and 0.5 mV s−1. CV profiles of the symmetric cells were collected on a Metrohm Autolab G204 Electrochemical Workstation.